12.07.2015 Views

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Setting Parameters01/02 AWB8230-1413GBCon<strong>tr</strong>olled decelerationNormally, in the event of a power failure or an Emergency-Stop,the motor coasts to a halt without frequency inverter con<strong>tr</strong>ol. Insome applications, however, it is necessary to con<strong>tr</strong>ol the motor’sdeceleration. This function is provided for such cases.To use this function, the power supply for connections R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0must be changed.Proceed as follows:X Release the two screws of terminals R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0. Removeconnector J51 with the cable from the circuit board (retain theplug).Warning!Before working on the <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong>, isolate the device from itspower supply. Risk of fatal injury from elec<strong>tr</strong>ical current.By default, terminals R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0 are connected to phases L1 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> L3through connector J51 (a fig. 144).R0 T0L1L2L3J51R0T0SMPSU–+VWBRDC–DC+L+M3 hJ51Figure 146: Disconnect J51 from terminals R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0Figure 144: Default connection of terminals R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0SMPS: <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> con<strong>tr</strong>ol elec<strong>tr</strong>onicsFor con<strong>tr</strong>olled deceleration to work, you must connect terminalsR0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0 to DC+ <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> DC– (a fig. 145).X Connect a cable to terminal R0, which is long enough to reachterminal DC+ (do not connect yet).X Connect a cable to terminal T0, which is long enough to reachterminal DC– (do not connect yet).X Remove the ferrite rings from the connector cable (J51) <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>guide the new cable through the ferrite rings.L1L2L3J51R0T0SMPSU–V M+ W 3 hBRDC–DC+L+T0R0Figure 147: Remove the ferrite rings.Figure 145: Connecting terminals R0 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T0 to DC+ <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> DC–SMPS: <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> con<strong>tr</strong>ol elec<strong>tr</strong>onicsX Twist the two cables with each other.X Connect terminal R0 to DC+ <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> terminal T0 to DC–.With this wiring arrangement, the motor can feed the frequencyinverter’s con<strong>tr</strong>ol elec<strong>tr</strong>onics when the power supply is switchedoff.140

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!