12.07.2015 Views

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Programming the Con<strong>tr</strong>olSignal Terminals01/02 AWB8230-1413GBAnalog setpoint value matchingThe external setpoint signal can be specifically matched withparameters PNU A011 to A016 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> A101 to A114, which aredescribed below. A configurable voltage or current setpoint rangecan be assigned to a configurable frequency range.Furthermore, analog setpoint signal filtering can be adjusted usingPNU A016.Matching analog input Ofigure 49 shows how to match the analog signal (0 to +10 V).With PNU A013 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> A014, you specify the active voltage range. InPNU A011, you can set the starting point, <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> in PNU A012 theend point for the output frequency. If the line does not start at theorigin, (PNU A011 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> A013 > 0), specify the starting frequencywith PNU A015. As long as the input signal is smaller than thevalue set in PNU A013, either 0 Hz (for PNU A015 = 00) orPNU A011 (for PNU A015 = 01) is output.f[Hz]PNU A004PNU A012PNU A011Figure 49:PNU A015 = 00PNU A015 = 010 V PNU A013 PNU A014 10 V0 % 100 %Setpoint matching, terminals O–LU O-LPNU Name Adjustable in RUN mode Value Function WENormalExtendedA011A012A013A014A015A016Startingfrequency,input OEnd frequency,input OMinimumsetpointvoltage, input OMaximumsetpointvoltage, input OCondition forstartingfrequency foranalog input OAnalog inputfilter timeconstant– j 0.00 to 400 Hz Here, you define the starting frequency for the minimumsetpoint voltage (PNU A013).– j 0.00 to 400 Hz Here, you define the end frequency for the maximumsetpoint voltage (PNU A014).– j 0 to 100 % Minimum setpoint voltage as a percentage of the greatestpossible voltage (+10 V).– j 0 to 100 % Maximum setpoint voltage as a percentage of the greatestpossible voltage (+10 V).– j Determines the behaviour at setpoint values below the minimum setpoint value. 0100 The frequency defined under PNU A011 is applied to themotor.01 A frequency of 0 Hz is applied to the motor.– j Averaging for attenuating any superimposed interference frequencies at analoginputs O, O2 or OI. The value between 1 <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> 30 specifies the number of valuesto be averaged.1 Low filtering effect, fast response to setpoint value changes....30 S<strong>tr</strong>ong filtering effect, delayed response to setpoint valuechanges0.000.000100862

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!