Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr
Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr
Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Programming the Con<strong>tr</strong>olSignal Terminals01/02 AWB8230-1413GBCon<strong>tr</strong>oller inhibit <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> coasting (free run stop – FRS)If you activate the digital input configured as FRS, the motor isswitched off <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> coasts to a stop (for example if an Emergency-Stop is made). If you deactivate the FRS input, then, depending onthe inverter’s configuration, the frequency output is eithersynchronized to the current speed of the coasting motor or restartsat 0 Hz.X Use PNU b088 to specify whether the motor is to restart at 0 Hzafter the FRS input has been deactivated, or if synchronizationshould take place after a waiting time specified underPNU b003. The frequency inverter recognizes the speed of therotor <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> starts only when the frequency set at PNU b007 isreached.X Program one of the digital inputs 1 to 5 as FRS by entering thevalue 11 under the corresponding PNU (C001 to C005).FWDFRSFW 3P24Figure 61:Digital input 3 configured as FRS (con<strong>tr</strong>oller inhibit) <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>FW as FWD (start/stop clockwise operation)FWD/REVFRSabn Mct wFigure 62: Function chart for FRS (con<strong>tr</strong>ol inhibit <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> free run stop)n M :Motor speedt w : Waiting time (setting under PNU b003)a Motor coasts to a stopb Synchronization to the current motor speedc Restart from 0 HzPNU Name Adjustable in RUN mode Value Function WENormalExtendedb003Waiting timebefore restart– j 0.3 to 100 s Here, set a time which is to expire before an automaticrestart is initiated after a fault signal. This time can also beused in conjunction with the FRS function. During the delay,the following message appears on the LED display:1.0b007b088SynchronizingfrequencyMotor restartafter removalof the FRSsignal– j 0 to 400 Hz <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at which a restart is initiated. 0.00– j 00 0 Hz restart after deactivation of the FRS input 0001 Synchronization of the motor to the frequency set underPNU 007 after the waiting time set under PNU b003.74