12.07.2015 Views

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Programming the Con<strong>tr</strong>olSignal Terminals01/02 AWB8230-1413GBCon<strong>tr</strong>oller inhibit <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> coasting (free run stop – FRS)If you activate the digital input configured as FRS, the motor isswitched off <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> coasts to a stop (for example if an Emergency-Stop is made). If you deactivate the FRS input, then, depending onthe inverter’s configuration, the frequency output is eithersynchronized to the current speed of the coasting motor or restartsat 0 Hz.X Use PNU b088 to specify whether the motor is to restart at 0 Hzafter the FRS input has been deactivated, or if synchronizationshould take place after a waiting time specified underPNU b003. The frequency inverter recognizes the speed of therotor <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> starts only when the frequency set at PNU b007 isreached.X Program one of the digital inputs 1 to 5 as FRS by entering thevalue 11 under the corresponding PNU (C001 to C005).FWDFRSFW 3P24Figure 61:Digital input 3 configured as FRS (con<strong>tr</strong>oller inhibit) <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>FW as FWD (start/stop clockwise operation)FWD/REVFRSabn Mct wFigure 62: Function chart for FRS (con<strong>tr</strong>ol inhibit <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> free run stop)n M :Motor speedt w : Waiting time (setting under PNU b003)a Motor coasts to a stopb Synchronization to the current motor speedc Restart from 0 HzPNU Name Adjustable in RUN mode Value Function WENormalExtendedb003Waiting timebefore restart– j 0.3 to 100 s Here, set a time which is to expire before an automaticrestart is initiated after a fault signal. This time can also beused in conjunction with the FRS function. During the delay,the following message appears on the LED display:1.0b007b088SynchronizingfrequencyMotor restartafter removalof the FRSsignal– j 0 to 400 Hz <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> at which a restart is initiated. 0.00– j 00 0 Hz restart after deactivation of the FRS input 0001 Synchronization of the motor to the frequency set underPNU 007 after the waiting time set under PNU b003.74

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!