12.07.2015 Views

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

01/02 AWB8230-1413GB Contents– Run signal (RUN) 96–Overload signal (OL) 97– PID con<strong>tr</strong>ol deviation signal (OD) 98– Fault signal (AL) 99– Instant stop (IP) <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> undervoltage (UV) 99– Running time (RNT) <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> Mains On time (ONT) 100– Motor thermal overload (THM) 1016 Setting Parameters 103Setting the display parameters 104Basic functions 105– Input/display frequency value 105– Acceleration time 1 105– Deceleration time 1 106– Direction of rotation 106Setting the frequency <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> start signal parameters 107– Defined frequency setpoint 107– Start signal 108– Base frequency 108– End frequency 108Voltage/frequency characteristic <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> voltage boost 109–Boost 109– Voltage/frequency characteristics 109DC braking (DCB) 112Operating frequency range 114Acceleration pause 115PID con<strong>tr</strong>ol 116– PID con<strong>tr</strong>ol 116– S<strong>tr</strong>ucture <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> parameters of the PID con<strong>tr</strong>oller 119– Example for setting K p <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> T i 125– Application examples 126Automatic voltage regulation (AVR) 128Energy-saving mode 128Time ramps 129Acceleration <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> deceleration characteristics 130Automatic restart after a fault 132Elec<strong>tr</strong>onic motor protection 135– Tripping characteristics with increasedoverload protection 135– Tripping characteristic with normal overload protection 136– Tripping characteristic at adjustable overload protection 136Current limit 138Parameter protection 139Con<strong>tr</strong>olled deceleration 140Other functions 142– Inhibit direction 142– Starting behaviour 142–Display mode 143– Pulse frequency 144– Initialization 147– Coun<strong>tr</strong>y version 147– <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> factor for display through PNU d007 147– OFF key disabled 147– Motor restart after removal of the FRS signal 1483

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!