01/02 AWB8230-1413GB St<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>ard form for user definedparameter settingsPNU Function Units WE Page Setpointb001Restart mode• 00: Fault message• 01: 0 Hz start• 02: Synchronization to current motor speed <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>acceleration• 03: Synchronization <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> deceleration– 00 133b002 Permissible power failure duration [s] 1.0 133b003 Waiting time before restart [s] 1.0 133b004 Fault message issued immediately• 00: No fault on intermittent mains failure• 01: Fault on intermittent mains failure• 02: No fault on intermittent mains failure atst<s<strong>tr</strong>ong>and</s<strong>tr</strong>ong>still <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> deceleration– 00 133b005b006Number of restart attempts• 00: 16 restart attempts• 01: Unlimited number of restart attemptsMains phase failure detection• 00: Inactive• 01: Active– 00 134– 00 134b007 Synchronization frequency on return of mains power [Hz] 0.00 134b012 Tripping current for elec<strong>tr</strong>onic motor protection device [A] I e (inverter) 136b212 Tripping current for elec<strong>tr</strong>onic motor protection device [A] I e (inverter) 136(second parameter set)b013 Characteristic for elec<strong>tr</strong>onic motor protection device• 00: Enhanced protection• 01: Normal protection• 03: User-definable protection– 01 136b213Characteristic for elec<strong>tr</strong>onic motor protection device(second parameter set)• 00: Enhanced protection• 01: Normal protection• 03: User-definable protectionb015 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> 1 for user-definable motor protectioncharacteristicb016 Tripping current 1 for user-definable motor protectioncharacteristicb017 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> 2 for user-definable motor protectioncharacteristicb018 Tripping current 2 for user-definable motor protectioncharacteristicb019 <s<strong>tr</strong>ong>Frequency</s<strong>tr</strong>ong> 3 for user-definable motor protectioncharacteristicb020 Tripping current 3 for user-definable motor protectioncharacteristicb021 Motor current limitation 1• 00: Inactive• 01: Active in every operating status• 02: Inactive during acceleration, otherwise active– 01 136[Hz] 0 137[A] 0.0 137[Hz] 0 137[A] 0.0 137[Hz] 0 137[A] 0.0 137– 01 138b022 Tripping current 1 for motor current limitation [A] I e x 1.5 138b023 Time constant 1 of motor current limitation [s] 1.00 138171

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!