12.07.2015 Views

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

Hardware and Engineering DF6-340-... Frequency ... - Moeller.com.tr

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

01/02 AWB8230-1413GB Other functionsDisplay modeWith this function, you can specify the parameters which the <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong>displays. Only these displayed parameters can then be changed:• All parameters: PNU b037 = 00 (default)• Parameters which are relevant to the programmed parameters:PNU b037 = 01• Only the parameters saved under PNU U001 to U012,PNU b0037 = 02 (a section “User-defined parameters –parameter group U”, page 150).All parameters: PNU b037 = 00 (default)By default, the <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> displays all parameters <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> all parameters canbe changed.Relevant parameters: PNU b037 = 01With this setting, the <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> displays only those parameters whichare connected with ones that are already programmed. If, forexample you set a constant V/f characteristic under PNU A044(default value: 00), the parameters for an adjustable V/fcharacteristic are not shown (PNU b100 to b113). The table belowshows, which parameters are hidden when this option is set.PNU Value PNUs which are hidden when PNU b037 isset to 01FunctionA001 01 A005, A006, A011 to A016, A101 to A105, A111 Analog inputs O, OI, O2to A114, C081 to C083, C121 to C123A002 01, 03, 04, 05 b087 OFF key disabledA019 00 A028 to A035 Fixed frequenciesC001 to C005 02, 03, 04, 05A044, A244 02 b100 to b113 Voltage <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> frequency characteristicA051 01 A052 to A059 DC brakingA071 01 A072 to A076, C044 PID con<strong>tr</strong>olA094 01 A095 to A096 Second time rampA294 01 A295 to A296b013, b213, b313 02 b015 to b020 Elec<strong>tr</strong>onic motor protectionb021 01, 02 b022, b023 Overcurrent limitb024 01, 02 b025, b026 Overcurrent limit 2b095 01, 02 b090, b096 BRD functionC001 to C005 06 A038, A039 Jog mode08 F202, F203, A203, A204, A220, A241 to A244,A261, A262, A292 to A296, b212, b213, H203 toH206Second parameter set11 b088 Motor shutdown <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> free run stop (coasting)18 C102 Reset27, 28, 29 C101 Acceleration/deceleration motor potentiometerA044 00, 01 A041 to A043 Voltage boost functionA244 00, 01 A241 to A243 Voltage boost functionA044 03, 04, 05 b040 to b046, H001, H002 0 Hz limitationA244 03, 04 b040 to b046, H202A097 01, 02, 03 A131 Curvature of acceleration rampA098 01, 02, 03 A132 Curvature of acceleration rampb098 01, 02 b099, C085 Thermistor functionb050 01 b051 to b054 Behaviour on power failureb120 01 b121 to b126 Brake con<strong>tr</strong>ol143

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!