Programming the Con<strong>tr</strong>olSignal Terminals01/02 AWB8230-1413GBHeavy mains starting (CS)The CS function is used for starting drives with an ex<strong>tr</strong>emely highstarting torque directly from the mains. This means that a smaller,less expensive frequency inverter can be used, since the <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> hasto deliver only the motor full load current, not the high startingcurrent (for example 50 A starting current, 15 A motor full loadcurrent).To use this function, the system must be wired as shown infigure 79.L1L2L3PEQ1135IIIQ11135IIIF11K2MK1MK11L1L2L3L1PEL1 L2 L3Z2Z1PER0 T0L1 L2 L3PEP24 FW2FWDCS<s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong>-<s<strong>tr</strong>ong>340</s<strong>tr</strong>ong>-...DV6-<s<strong>tr</strong>ong>340</s<strong>tr</strong>ong>-...U V W PE CM1 THK3MM1M 3 heFigure 79: <s<strong>tr</strong>ong>DF6</s<strong>tr</strong>ong> series frequency inverters with K2M bypass contactor, K3M motor contactor <s<strong>tr</strong>ong>and</s<strong>tr</strong>ong> K1M mains contactorF11: 6 A miniature circuit-breaker, for example FAZ-B688