12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

13.5 Reference Percentage ChannelThe reference percentage channel combines various signal sources for definition ofthe reference values. The percentage scaling facilitates integration into the application,taking various process parameters into account.The Reference Percentage Source 476 determines the additive assignment of theavailable reference value sources depending on the hardware installed.Operation modeFunctionReference value source is the multifunctional1 - Abs. Analog Value MFI1Ainput 1 in Operation Mode 452 - Analog signal.The percentage according to Fixed Percent10 - Abs. Fix. Perc. Val. (FP) Change-Over 1 75, Fixed Percent Change-Over 276 and the current data set11 - Abs. Value MFI1A + FP Combination of operation modes 1 and 10Reference value source is the function Percent20 - Abs. Value Motorpoti (MP) Motorpoti Up 72 and Percent Motorpoti Down7321 - Abs. Value MFI1A + MP Combination of operation modes 1 and 20The frequency signal on the digital input accordingto Operation Mode 496 of the repetition fre-Abs. Repetition <strong>Frequency</strong>32 -Input (F3)quency input33 - Abs. Val. MFI1A + F3 Combination of operation modes 1 and 32Abs. Value MFI1A + FP + Combination of the operation modes 1, 10, 20, 3290 -MP + F3 (+ EM-S1INA) 1) (+ analog input of an extension module) 1)101 to 190 Operation modes with signs (+/-)1)The reference value source is only available if an optional extension module withanalog input is connected. For information, refer to the extension module operatinginstructions.13.5.1 Block DiagramThe following table describes the software switches shown in the circuit diagram as afunction of the selected Reference Percentage Source 476.Switch position on circuit diagramOperationmodeMFI1A FP MP F3 Sign1 1 Abs. value10 1 Abs. value11 1 1 Abs. value20 1 Abs. value21 1 1 Abs. value32 1 Abs. value33 1 1 Abs. value90 1 1 1 1 Abs. value101 1 +/-110 1 +/-111 1 1 +/-120 1 +/-121 1 1 +/-132 1 +/-133 1 1 +/-190 1 1 1 1 +/-02/06 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!