12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

14.3.4 Open brakeThe Open brake function in operation mode 41 enables the activation of a correspondingunit via the digital control output. The function uses both the control commandsvia the contact inputs and the set starting and stopping behavior for controllingthe digital output.According to the configured starting behavior, the output is switched on when themagnetizing of the motor is finished. The brake is released and the drive is accelerated.The stopping behavior of the drive depends on the configuration of the parametersOperation Mode 630. This is described in chapter "Stopping Behavior".If stopping behavior 2 or 5 with stop function is selected, the drive is controlled tozero speed and the digital output is not switched off. In the other operation modes ofthe stop behavior, the control of the brake is possible. At the start of a free coastingof the drive, the digital output is switched off.This is similar to the behavior in the case of the stopping behavior with shutdown. Thedrive is decelerated and supplied with current for the set holding time. Within the setholding time, the control output is switched off and thus the brake activated.Stopping Behavior0Stopping Behavior1, 3, 4, 6, 7Stopping Behavior2, 5Control of BrakeOperation mode "41-Open brake" switches off the digitaloutput assigned to the function immediately. The mechanicalbrake is activated.Operation mode "41-Open brake" switches off the digitaloutput assigned to the function when Switch-Off Threshold637 is reached. The mechanical brake is activated.Operation mode "41-Open brake" leaves the digital outputassigned to the function switched on. The mechanicalbrake remains open.14.3.5 Current LimitationOperation modes 15 to 19 link the digital outputs and the relay output to the functionsof the intelligent current limits. The reduction of power by the set figure in percentof the rated current depends on the selected operation mode. Accordingly, theevent for intervention of the current limitation can be output via the operation modesof the digital outputs. If the function of the intelligent current limits is deactivatedwithin the sensor-less control, operation modes 16 to 19 are switched off in the sameway.14.3.6 External FanOperation mode 43 enables the control of an external fan. Via the digital output, thefan is switched on if the controller is released and Start clockwise or Start anticlockwiseare switched on, or if the Switch-On Temperature 39 for the internal fan wasreached.02/06 125

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!