12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

14.3 Digital OutputsThe OP. Mode Digital Output 1 530 and the relay output with the parameter Op.Mode Digital Output 3 532 link the digital outputs to various functions. The selectionof the functions depends on the parameterized configuration. The use of the multifunctionaloutput MFO1 as a digital output demands selection of an Operation Mode550 and linking via parameter Digital Operation 554.Operation modeFunction0 - Off Digital output is switched off<strong>Frequency</strong> inverter is initialized and on stand-by1 - Ready or Standby Signalor in operationController release signal and a start command are2 - Run Signalpresent, output frequency availableMessage is displayed via the parameter Current3 - Error SignalError 259 or Warnings 269.The Stator <strong>Frequency</strong> 210 is higher than the4 - Setting <strong>Frequency</strong>parameterized Setting <strong>Frequency</strong> 510Reference <strong>Frequency</strong> The Actual <strong>Frequency</strong> 241 of the drive has5 -reachedreached the Internal Reference <strong>Frequency</strong> 228.Reference Percentage The Actual Percentage Value 230 has reached6 -Reachedthe Reference Percentage Value 229.The Warning Limit Short-Term Ixt 405 or WarningLimit Long-Term Ixt 406 has been reached.7 - Ixt warning8 - WarningMax. heat sink temperature T K of 80 °C minus theHeat sink temperature Warning Limit Heat Sink Temp. 407 reached.9 - WarningMax. inside temperature T i of 65 °C minus theInside temperature Warning Limit Inside Temperature 408 reached.Warning behavior according to parameterized10 - Warning Motor Temperature Motor Temp. Operation Mode 570 at max. motortemperature T PTC .The message is displayed via parameter Warnings11 - Warning General269.The selected limit values Warning Limit Heat SinkTemp. 407, Warning Limit Inside Temp 408 or12 - Warning over temperaturethe maximum motor temperature have been exceeded.Failure of the mains voltage and power regulation13 - Mains Failureactive according to Operation Mode 670 for thevoltage controller.Warning Motor Protect. Parameterized Operation Mode 571 for the motor14 -Switchprotection switch has triggered.A controller or the Operation Mode 573 of the15 - Warning Current Limitationintelligent current limits limit the output current.Controller Current Limit. The overload reserve for 60 s has been used up16 -Long Term Ixtand the output current is being limited.Controller Current Limit. The overload reserve for 1 s has been used up17 -Short Term Ixtand the output current is being limited.Max. heat sink temperature TK reached, intelligentcurrent limits of Operation Mode 573 active.18 - Controller Current Limit. TKController Current Limit. Max. motor temperature reached, intelligent currentlimits of Operation Mode 573 active.19 -Motor Temp.The comparison according to the selected OP.20 - Comparator 1mode Comparator 1,540 is true.Table "Operation Modes for Digital Outputs" continued on next page.02/06 123

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!