12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Operation modeFunctionThe DC link voltage has exceeded the Reference33 - Controller Udc LimitationDC-Link Limitation 680.34 - ControllerThe Dyn. Voltage Pre-Control 605 accelerates theVoltage Pre-Control control characteristics.35 - Controller I abs The output current is limited36 - ControllerThe output power or the torque are limited on theTorque Limitation speed controller37 - ControllerSwitch-over of field-orientated control betweenTorque Controlspeed and torque-controlledThe Operation Mode 620 selected in starting behaviorlimits the output current38 - Ramp StopContr. Intel. Curr. Lim. Overload limit of the long-term Ixt (60s) reached,39 -LT-Ixtintelligent current limits activeContr. Intel. Curr. Lim. Overload limit of the short-term Ixt (1s) reached,40 -ST-Ixtintelligent current limits activeContr. Intel. Curr. Lim. Max. heat sink temperature T41 - K reached, OperationTcMode 573 for the intelligent current limits active.Contr. Intel. Curr. Lim. Max. motor temperature T42 - PTC reached, OperationMotor Temp.Mode 573 for the intelligent current limits active.43 - ControllerThe reference frequency has reached the MaximumTorque Limitation <strong>Frequency</strong> 419. The frequency limitation is active.Removal or deactivation of the operation mode101 to 143within the warning maskThe selected warning mask can be read out via the parameter Actual Warning Mask537. The above operation modes, which can be set in the configurable Create WarningMask 536 are encoded in the Actual Warning Mask 537. The code results fromhexadecimal addition of the individual operation modes and the matching abbreviation.Warning code Operation mode 536A FFFF FFFF - 1 - Activate everythingA 0000 FFFF - 2 - Activate all WarningsA FFFF 0000 - 3 - Activate all Controller StatesA 0000 0001 Ixt 10 - Warning IxtA 0000 0002 IxtSt 11 - Warning Short-Term IxtA 0000 0004 IxtLt 12 - Warning Long-Term IxtA 0000 0008 Tc 13 - Warning Heat Sink TemperatureA 0000 0010 Ti 14 - Warning Inside TemperatureA 0000 0020 Lim 15 - Warning LimitA 0000 0040 INIT 16 - Warning InitA 0000 0080 MTemp 17 - Warning Motor TemperatureA 0000 0100 Mains 18 - Warning Phase FailureA 0000 0200 PMS 19 - Warning Motor Protection SwitchA 0000 0400 Flim 20 - Warning FmaxA 0000 0800 A1 21 - Warning Analog Input MFI1AA 0000 1000 A2 22 - Warning Analog Input MFI2AA 0000 2000 Sysbus 23 - Warning System busA 0000 4000 UDC 24 - Warning UdcA 0000 8000 BELT 25 - Warning V-beltTable "Operation Modes of Warning Mask" continued on next page.02/06 127

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!