7.2.2 Data SetThe data set change-over function enables the selection of one of four data sets forstoring parameter settings.If data set 0 is selected (factory setting), the parameter values stored in data set 0 arecopied to data sets 1 through 4. In this way, all values determined during the guidedcommissioning procedure are saved in all data sets. In the factory settings, the frequencyinverter uses data set 1 as the active data set. (For information on data setchange-over via logic signals, refer to the chapter "Data Set Change-Over")For example, if data set 2 is selected for guided commissioning ("SETUP"), all valueswhich were determined or entered are saved in this data set. In this case, the otherdata sets do not contain any defined values. For the operation of the frequency inverter,data set 2 must be selected as the active data set in this case.Data Set SetupdSFunction0 All data sets (DS0)1 Data set 1 (DS1)2 Data set 2 (DS2)3 Data set 3 (DS3)4 Data set 4 (DS4)7.2.3 Motor TypeThe properties of the control functions and methods to be set vary depending on themotor which is connected. The parameter Motor type 369 offers a range of motorvariants with the corresponding table values. The verification of the entered rated valuesand the guided commissioning are carried out on the basis of the parameterizedmotor type. The selection of motor types varies depending on the requirements of thedifferent control methods. In operating instructions the functionality and operatingperformance are described for 3-phase motors.Operation modeFunction0 - Unknown The motor is not a standard type.1 - Asynchronous Three-phase asynchronous motor, squirrel cage2 - Synchronous Three-phase synchronous motor3 - Reluctance Three-phase reluctance motor10 - Transformer Transformer with three primary windingsCaution!Polling and presetting of parameter values depends on the operation modeselected for parameter Motor type 369.If the motor type is not entered correctly, the drive may be damaged.When the motor type is specified, the machine data must be entered. This is describedin the following chapter. The data are polled in accordance with the table below.64 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!