−−−The output value of the controller is limited by an upper and a lower torque limit,parameter Torque Limit 730 and parameter Torque Limit Generator Op.. 731.The limit values are input as a percentage of the rated motor torque. The assignmentof fixed values or analog limit values is done via the parameters TorqueLimit Source Motor Op. 736 and Torque Limit Source Gen. Op 737.The output value of the P component is limited with parameter P-Comp. TorqueUpper Limit 732 and P-Comp. Torque Lower Limit 733. The limit values are inputas torque limits as a percentage of the rated motor torque.The power output by the motor is proportional to the product of speed andtorque. This output power can be limited at the controller output with a PowerLimit 739 and Power Limit Generator Operation 740. The power limits are enteredin kW.ParameterSettingsNo. Description Min. Max. Fact. sett.728 Current Limit 0.0 A o ⋅ I FIN o ⋅ I FIN729 Current Limit Generator Operation -0.1 A o ⋅ I FIN o ⋅ I FIN730 Torque Limit 0.00 % 650.00 % 650.00 %731 Torque Limit Generator Operation 0.00 % 650.00 % 650.00 %732 P-Comp. Torque Upper Limit 0.00 % 650.00 % 100.00 %733 P-Comp. Torque Lower Limit 0.00 % 650.00 % 100.00 %739 Power Limit 0.00 kW 2⋅o⋅P FIN 2⋅o⋅P FIN740 Power Limit Generator Operation 0.00 kW 2⋅o⋅P FIN 2⋅o⋅P FIN16.5.3.2 Limit Value SourcesAs an alternative to limiting the output values by a fixed value, linking to an analoginput value is also possible. The analog value is limited via parameters Minimum ReferencePercentage 518 and Maximum Reference Percentage 519, but does not considerthe Gradient Percentage Ramp 477 of the reference percentage value channel.The assignment is done with the help of the parameters Isq Limit Source Motor Operation734 and Isq Limit Source Generator Op. 735 for the torque-forming currentcomponent Isq.The sources for torque limits are selectable via parameters Torque Limit Source MotorOp 736 and Torque Limit Source Gen. Op.737Operation mode101 - Analog Input MFI1A105 - Rep. <strong>Frequency</strong> Input (F3)110 - Fixed LimitFunctionThe source is the multifunctional input 1 in ananalog Operation Mode 452.The frequency signal on the repetition frequencyinput corresponding to Operation Mode 496The selected parameter values for limiting thespeed controller are taken into account.Note:The limit values and assignment to different limit value sources are dataset related in the configurations. The use of the data set change-overdemands an examination of the parameters in question.02/06 157

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!