Stopping behavior 0Free stoppingStopping behavior 1Stop+ Switch offStopping behavior 2Stop + HoldStopping behavior 3Stop + DC brakesStopping behavior 4Emergency stop+ switch offStopping behavior 5Emergency stop +HoldStopping behavior 6Emergency stop +BrakeStopping behavior 7Direct current brakeStopping BehaviorThe inverter is disabled immediately. The drive deenergizedimmediately and coasts freely.The drive is brought to a standstill at the set deceleration.As soon as the drive is at a standstill, the inverter is disabledafter a holding time. The holding time can be set viathe parameter Holding Time 638.Depending on the setting of the parameter Starting Function620, the Starting Current 623 is impressed or theStarting Voltage 600 is applied for the duration of theholding time.The drive is brought to a standstill at the set decelerationand remains permanently supplied with current.Depending on the setting of the parameter Starting function620, the Starting Current 623 is impressed as fromstandstill or the Starting Voltage 600 is applied.The drive is brought to a standstill at the set deceleration.As from standstill, the direct current set via parameterBraking Current 631 is impressed for the Braking Time632.Comply with the notes in chapter "DC brake".Stopping behaviors 3, 6 and 7 are only available in theconfigurations for sensor-less control.The drive is brought to a standstill at the emergency stopdeceleration. As soon as the drive is at a standstill, theinverter is disabled after a holding time.The holding time can be set via the parameter HoldingTime 638. Depending on the setting of the parameterStarting Function 620, the Starting Current 623 is impressedas from standstill or the Starting Voltage 600 isapplied.The drive is brought to a standstill at the set emergencystop deceleration and remains permanently supplied withcurrent.Depending on the setting of the parameter Starting Function620, the Starting Current 623 is impressed as fromstandstill or the Starting Voltage 600 is applied.The drive is brought to a standstill at the set emergencystop deceleration. As from standstill, the direct current setvia parameter Braking Current 631 is impressed for theBraking Time 632.Comply with the notes in chapter "DC brake".Stopping behaviors 3, 6 and 7 are only available in theconfigurations for sensor-less control.Direct current braking is activated immediately. The directcurrent set with the parameter Braking Current 631 isimpressed for the die Braking Time 632.Comply with the notes in chapter "DC brake".Stopping behaviors 3, 6 and 7 are only available in theconfigurations for sensor-less control.02/06 87

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!