12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

16.3 Technology ControllerThe technology controller, the behavior of which corresponds to a PI controller, isavailable as an additional function in configuration 111 and 411. The connection ofreference and actual value of the application with the functions of the frequency inverterenables process control without further components. In this way, applicationssuch as pressure, volume flow or speed control can be implemented easily.The configuration of the reference percentage source and the assignment of the actualpercentage source are to be considered.Structural image:Technology controllerReferencepercentage source 476-Actual percentage source 478Actual values:Actual percentage value 230Reference percentage value 229For the reference value, the technology controller also demands the assignment of ananalog application value with the parameter Actual Percentage Source 478. The differencebetween reference and actual value is used by the technology controller tocontrol the drive system. The measured actual value is mapped via a signal converteronto the input signal of the reference percentage source.Operation mode1 - Analog Input MFI1A32 -Rep. <strong>Frequency</strong> Input(F3)FunctionThe analog signal on the multifunctional input 1 inOperation Mode 452 - analog operationThe frequency signal at the digital input according tothe selected Operation Mode 496Caution!The default assignment of parameter Start Clockwise 68 to the logicsignal of the technology controller must be observed. The technologycontroller becomes active with the controller release at digital inputS1IND.As soon as the signals Controller release and Start clockwise or Start Anticlockwiseare present, the drive will rotate.The function selected via the parameter Operation Mode 440 defines the behavior ofthe technology controller0 - OffOperation mode1 - Standard2 - Liquid Level 13 - Liquid Level 24 - Speed controller5 -Indirect volume flowcontrolFunctionThe technology controller is switched off, the referencevalue specification is done via the reference percentagechannel.For pressure and volume flow control with linear operatingbehavior and actual value monitoringContents level control at defined motor speed withactual value missingContents level control at defined motor speed withactual value missing or high control deviationSpeed control with analog feedback of the actualspeedPressure or volume flow control with square rootedactual value02/06 149

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!