3.2 <strong>Frequency</strong> <strong>Inverter</strong> 400 V (0.55 up to 4.0 kW)TypeACT 401 -05 -07 -09 -11 -12 -13 -15 -18Output. motor sideRecommended shaft output P kW 0.55 0.75 1.1 1.5 1.85 2.2 3.0 4.0Output current I A 1.8 2.4 3.2 3.8 3) 4.2 5.8 7.8 9.0 3)Long-term overload current (60 s) I A 2.7 3.6 4.8 5.7 6.3 8.7 11.7 13.5Short-term overload current (1 s) I A 3.6 4.8 6.4 7.6 8.4 11.6 15.6 18.0Output voltage U V 3 x 0 ... mains voltageDegree of protection - - Short circuit / earth fault proofRotary filed frequency f Hz 0 ... 1000, depending on switching frequencySwitching frequency f kHz 2. 4. 8. 12. 16Output brake resistormin. brake resistor (U dBC = 770 V) R Ω 930 634 462 300 300 220 148 106Input, mains sideMains current 2) 3ph/PE I A 1.8 2.4 2.8 1) 3.3 1) 4.2 5.8 6.8 1) 7.8 1)Mains voltage U V 320 ... 528Mains frequency f Hz 45 ... 66Fuse 3ph/PE I A 6 10UL-Type 600 VAC RK5. 3ph/PE I A 6 10MechanicsDimensions HxWxD mm 190x60x175 250x60x175Weight (approx.) m kg 1.2 1.6Degree of protection - - IP20 (EN60529)Terminals A mm 2 0.2 ... 1.5Form of assembly - - verticalAmbient conditionsEnergy dissipation(2 kHz Switching frequency)P W 40 46 58 68 68 87 115 130Coolant temperature T n °C 0 ... 40 (3K3 DIN IEC 721-3-3)Storage temperature T L °C -25 ... 55Transport temperature T T °C -25 ... 70Rel. air humidity - % 15 ... 85; not condensingIf required by the customer, the switching frequency may be increased if the output current is reduced at thesame time. Comply with the applicable standards and regulations for this operating point.Output current<strong>Frequency</strong> inverter nominal powerSwitching frequency2 kHz 4 kHz 8 kHz 12 kHz 16 kHz0.55 kW 1.8 A 1.8 A 1.8 A 1.5 A 1.2 A0.75 kW 2.4 A 2.4 A 2.4 A 2.0 A 1.6 A1.1 kW 3.2 A 1) 3.2 A 1) 3.2 A 1) 2.7 A 1) 2.2 A1.5 kW 1) 3.8 A 3.8 A 3) 3.8 A 3) 3.2 A 3) 2.6 A 3)1.85 kW 4.2 A 4.2 A 4.2 A 3.5 A 2.9 A2.2 kW 5.8 A 5.8 A 5.8 A 4.9 A 3.9 A3.0 kW 7.8 A 1) 7.8 A 1) 7.8 A 1) 6.6 A 1) 5.3 A4.0 kW 9.0 A 1) 9.0 A 1) 3) 9.0 A 1) 3) 7.6 A 1) 3) 6.1 A 3)1) Three-phase connection requires a commutating choke.2)Mains current with relative mains impedance ≥ 1% (see chapter„Electrical installation“)3) Switching frequency is reduced in thermal limit range02/06 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!