6.6 Read data from the KP 500 control unitThe Parameter transfer operation mode enables the transmission of data from theKP 500 control unit to the frequency inverter. In this operation mode, all functions ofthe control unit are disabled except for the COPY function. Data transmission from thefrequency inverter to the control unit is also disabled.Activation of the KP 500 control unit for Parameter transfer mode is prepared via theparameter Program(ming) 34. For this purpose, the KP 500 control unit must be connectedto the frequency inverter.Operation modeFunctionThe KP 500 control unit is prepared for parameter111 - Parameter transfer transmission. A connected frequency inverter can receivedata from the control unit.110 - Normal mode Reset the KP 500 control unit to standard modeAttention! The KP 500 control unit can be activated for Parameter transfer only ifat least one file is stored in the control unit. Otherwise, the error message"F0A10" will be displayed.6.6.1 ActivatingThe KP 500 control unit can be configured both via the keys of the KP 500 and via anyother available CM communication module. To configure and activate the KP 500 controlunit, proceed as follows:Activation via keyboard of the control unit• In the parameter menu PARA, use the arrow keys to select parameter Program(ming)34 and confirm the selection by pressing the ENT key.• Use the arrow keys to enter the value 111 – Parameter transfer and confirm yourselection by pressing the ENT key.Now, the control unit is ready for activation.Before data can be transferred, the control unit must be initialized.• Disconnect the control unit from the frequency inverter and re-connect it to thesame or another frequency inverter.The initialization operation is started. During the initialization, init and a progressindicator are displayed. After the initialization, the KP 500 control unit is ready fortransferring data to the frequency inverter.Note:Setting the parameter Program(ing) 34 to 111 – Parameter transfercan be undone by means of the control unit, provided that the controlunit has not been initialized yet.• In parameter Program(ing) 34, use the arrow keys to enter thevalue 110 – Normal Mode and confirm by pressing the ENT key.02/06 57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!