12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Operation modeFunction158 - Timer 1Output signal of the time function according tothe input connection Timer 1 83159 - Timer 2Output signal of the time function according tothe input connection Timer 2 84Reference <strong>Frequency</strong> Signal when the Actual <strong>Frequency</strong> 241 has163 -reachedreached the reference frequency164 - Setting <strong>Frequency</strong>Signal when the Setting <strong>Frequency</strong> 510 is smallerthan or equal to the Actual <strong>Frequency</strong> 241165 - Warning IxtThe monitoring functions report an overload ofthe frequency inverter166 - WarningMax. heat sink temperature T K of 80 °C less theHeat sink temperature Warning Limit Heat Sink Temp 407 reached167 - WarningMax. inside temperature T i of 65 °C less theInside temperature Warning Limit Inside Temp. 408 reachedWarning behavior according to parameterized168 - WarningMotor Temp. Operation mode 570 at max. motorMotor Temperaturetemperature T PTC .169 - General WarningSignal when Warnings 269 are displayed with acritical operating pointThe selected limit values Warning Limit Heat Sink170 - Warning Over temperatureTemp. 407, Warning Limit Inside Temp 408 orthe maximum motor temperature have been exceeded.171 - Output Comparator 1The comparison according to the selected OP.mode Comparator 1,540 is true.Inverted OutputOperation mode 171 with inverted logic172 -Comparator 1(LOW active)173 - Output Comparator 2The comparison according to the selected OP.mode Comparator 2 543 is true.Inverted OutputOperation mode 173 with inverted logic174 -Comparator 2(LOW active)175 - Digital Signal 1Signal, according to parameterizedOperation Digital Output 1 530Signal according to parameterized176 - Digital Signal 2Digital Operation 554 at multi-function outputMFO1177 - Digital Signal 3Signal, according to parameterizedOperation Mode Digital Output 3 532Reference Percentage Signal when the Actual Percentage Value 230178 -Reachedhas reached the Reference Percentage Value 229Failure of the mains voltage and power regulation179 - Mains Failureactive according to Operation Mode 670 for thevoltage controller.180 - WarningParameterized Operation Mode 571 of the motorMotor Protection Switch protection switch has triggered.220 - Logic module 1Signal from output of logic module 1, according toparameterized Operation Mode Logic 1 198221 - Logic module 1 inverted Inverted signal from output of logic module 1222 - Logic module 2Signal from output of logic module 2, according toparameterized Operation Mode Logic 1 201223 - Logic module 2 inverted Inverted signal from output of logic module 2Table "Operation Modes for Digital Control Signals" continued on next page.02/06 129

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!