12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6 Control Unit KP500The optional KP500 control unit is a practical tool for controlling the frequency inverterand setting and displaying the frequency inverter parameters.The control unit is not absolutely necessary for the operation of the frequency inverterand can be plugged on when required.ABFCDGEHIJKeysA RUN Used for starting the drive and opening the CTRL menu.Press the RUN key to open the motor potentiometer function.STOP Used for opening the CTRL menu, stopping the drive and acknowledgingfaultsJ ▲ ▼ Used for navigating in the menu structure and selecting parameters.Used for increasing/decreasing parameter values.ENT Used for opening parameters or switching to another menu within the menustructure. Confirmation of the selected function or the set parameter.ESC Used for aborting parameters or switching back to the previous menu withinthe menu structure. Canceling the function or resetting the parameter value.FUN Used for switching over the key function, access to special functions.DisplayB Three-digit 7-segment display to show the parameter numberC One-digit 7-segment display for display of the active data record, direction of rotationetc.D Display of the selected menu branch:VAL Display actual valuesPARA Select parameters and adjust parameter values.CTRL Select a function for adjustment and/or display via the control unit:SEtUP guided commissioningCtrL motor potentiometer and jog functionCPY Copy parameters via the control unit:ALL All the parameter values are copied.Act Only the active parameter values are copied.FOr Control unit memory is formatted and deleted.E Status and operating messages:WARN Warning about a critical operating behaviorFAULT Message indicating that the unit was switched off due to a faultRUN Flashing: signals readiness for operationLights up: signals that the unit is operating and the output stage is enabledREM Active remote control via interface connectionF Function switch-over with the FUN keyF Five-digit 7-segment display for display of parameter value and signG Physical unit of the parameter value displayedH Active acceleration or deceleration rampI Current direction of rotation of the drive02/06 49

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!