14.3.7 Warning MaskThe logic signals of various monitoring and control functions can be set via the operationmode for parameter Create Warning Mask 536. According to the application, anynumber of warnings and controller status messages can be combined. This enablesinternal or external control via a common output signal.Operation modeFunction0 - No Change Configured warning mask is not modified.1 - Activate everythingThe warnings and controller status messages statedare linked in the warning mask.2 - Activate all WarningsThe warnings reports stated are linked in the warningmask.Activate all Controller The controller status reports stated are linked in the3 -Stateswarning mask.10 - Warning Ixt The frequency inverter is overloaded11 - Warning Short-Term IxtOverload reserve for 1 s minus the Warning LimitShort-Term Ixt 405 has been reached.12 - Warning Long-Term IxtOverload reserve for 60 s minus the Warning LimitLong-Term Ixt 406 has been reached.Max. heat sink temperature T K of 80 °C minus theWarning Heat Sink Temperature13 - Warning Limit Heat Sink Temperature 407 hasbeen reached.14 - WarningMax. inside temperature T i of 65 °C minus theInside Temperature Warning Limit Inside Temperature 408 reached.15 - Warning LimitThe controller stated in Controller Status 355 limitsthe reference value.16 - Warning Init <strong>Frequency</strong> inverter is initialized17 -Warning Motor Temperature18 - WarningPhase Failure19 - WarningMotor Protection Switch20 - Warning Fmax21 - WarningAnalog Input MFI1A22 - WarningAnalog Input EM-S1INA23 - WarningSystem bus24 - Warning Udc25 - Warning V-belt30 - ControllerUdc Dynamic Operation31 - Controller Shutdown32 - Controller Mains FailureWarning behavior according to parameterized MotorTemp. Operation Mode 570 at max. motortemperature T PTC .Phase Supervision 576 reports a phase failure.Operation Mode 571 for the motor protectiveswitch has triggered.The Maximum <strong>Frequency</strong> 419 has been exceeded.The frequency limitation is activeThe input signal is lower than 1V/2mA according tothe operation mode Error/Warning Behavior 453The input signal is lower than 1V/2mA according tothe operation mode Error/Warning Behavior 453A Slave at the system bus signals a fault;Warning is only relevant with option EM-SYS.The DC link voltage has reached the typedependentminimum value.The Operation Mode 581 for V-belt monitoringsignals no-load operation of the application.Controller is active according to the OperationMode 670 for the voltage controller.The output frequency in the case of a mains failureis below the Shutdown Threshold 675.Failure of the mains voltage and power regulationactive according to Operation Mode 670 for thevoltage controller.126 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!