3 Technical Data3.1 <strong>Frequency</strong> <strong>Inverter</strong> 230 V (0.55 up to 3.0 kW)TypeACT 201 -05 -07 -09 -11 -13 -15Output. motor sideRecommended shaft output P kW 0.55 0.75 1.1 1.5 2.2 3.0 4)Output current I A 3.0 4.0 5.4 5) 7.0 9.54) 5)12.5Long-term overload current (60 s) I A 4.5 6.0 7.3 10.5 14.3 16.2Short-term overload current (1 s) I A 6.0 8.0 8.0 14.0 19.0 19.0Output voltage U V 3 x 0 ... mains voltageDegree of protection - - Short circuit / earth fault proofRotary field frequency f Hz 0 ... 1000, depending on switching frequencySwitching frequency f kHz 2. 4. 8. 12. 16Output brake resistormin. brake resistor (U dBC = 385 V) R Ω 230 160 115 75 55 37Input, mains sideMains current 3) , 3ph/PE3 4 5.5 1) 7 9.5 10.5 1)I A1ph/N/PE ; 2ph/PE5.4 7.2 9.5 2) 13.2 16.5 2) 2) 4)16.5Mains voltage U V 184 ... 264Mains frequency f Hz 45 ... 66Fuse 3ph/PE61016 16I A1ph/N/PE ; 2ph/PE101620 20UL Type 250 VAC RK5, 3ph/PE61015 15I A1ph/N/PE; 2ph/PE101520 20MechanicsDimensions HxWxD mm 190x60x175 250x60x175Weight (approx.) m kg 1.2 1.6Degree of protection - - IP20 (EN60529)Terminals A mm 2 0.2 ... 1.5Form of assembly - - verticalAmbient conditionsEnergy dissipation(2 kHz switching frequency)P W 43 53 73 84 115 170Coolant temperature T n °C 0 ... 40 (3K3 DIN IEC 721-3-3)Storage temperature T L °C -25 ... 55Transport temperature T T °C -25 ... 70Rel. air humidity - % 15 ... 85; not condensingIf required by the customer, the switching frequency may be increased if the output current is reduced at thesame time. Comply with the applicable standards and regulations for this operating point.Output current<strong>Frequency</strong> inverter nominal powerSwitching frequency2 kHz 4 kHz 8 kHz 12 kHz 16 kHz0.55 kW 3.0 A 3.0 A 3.0 A 2.5 A 2.0 A0.75 kW 4.0 A 4.0 A 4.0 A 3.4 A 2.7 A1.1 kW 5.4 A 2) 5.4 A 2) 5) 5.4 A 2) 5) 4.5 A 2) 5) 3.7 A 5)1.5 kW 7.0 A 7.0 A 7.0 A 5.9 A 4.8 A2.2 kW 9.5 A 2) 9.5 A 2) 9.5 A 2) 8.0 A 2) 6.5 A3.0 kW 2) 4) 12.5 A 1) 12.5 A 1) 5) 12.5 A 1) 5) 10.5 A 1) 5) 8.5 A 5)1)Three-phase connection requires a commutating choke.2)One- and two-phase connection requires a commutating choke.3) Mains current with relative mains impedance ≥ 1% (see chapter„Electrical installation“)4) Maximum output current is 9.5 A for one- and two-phase connection.5) Switching frequency is reduced in thermal limit range16 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!