5.6.2.4 Configuration 411 – Sensorless Field-Oriented Controlwith Technology ControllerConfiguration 411 extends the functionality of the sensor-less field-oriented control ofConfiguration 410 by a Technology Controller. The Technology Controller enables acontrol based on parameters such as flow rate, pressure, filling level or speed.M-+-V++-X210A1 +20 V/180 mA2 GND 20 V3 S1IND4 S2IND5 S3IND6 S4IND7 S5INDX210BS6IND1234567GND 20 VS1OUTMFO1A+10 V/4 mAMFI1AGND 10 VControl terminal X210AX210A.1 Supply voltage +20VX210A.2 Ground 20 VX210A.3 Controller release / error acknowledgmentX210A.4 Fixed percentage valuechange-over 1X210A.5 no function assignedX210A.6 Data set change-over 1X210A.7 Data set change-over 2Control terminal X210BX210B.1 Motor thermal contactX210B.2 Ground 20 VX210B.3 <strong>Operating</strong> messageX210B.4 Analog signal of actual frequencyX210B.5 Supply voltage +10VX210B.6 Actual percentage value 0 ...+10 VX210B.7 Ground 10 V5.6.2.5 Configuration 430 – Sensorless Field-Oriented Control,speed or torque controlledConfiguration 430 extends the functionality of the sensor-less field-oriented control ofConfiguration 410 by a Torque Controller. The reference torque is represented as apercentage and it is transmitted into the corresponding operational performance ofthe application. Change-over between variable-speed control and torque-dependentcontrol is done via a digital control input.M-+-V+X210A1 +20 V/180 mA2 GND 20 V3 S1IND4 S2IND5 S3IND6 S4IND7 S5INDX210BS6IND1234567GND 20 VS1OUTMFO1A+10 V/4 mAMFI1AGND 10 VControl terminal X210AX210A.1 Supply voltage +20VX210A.2 Ground 20 VX210A.3 Controller release / error acknowledgmentX210A.4 Start of clockwise operationX210A.5 n-/T change-over control functionX210A.6 Data set change-over 1X210A.7 Data set change-over 2Control terminal X210BX210B.1 Motor thermal contactX210B.2 Ground 20 VX210B.3 <strong>Operating</strong> messageX210B.4 Analog signal of actual frequencyX210B.5 Supply voltage +10 VReference value potentiometerX210B.6 Reference speed 0 ...+10 VX210B.7 Ground 10 V46 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!