In case the sense of rotation is wrong, exchange two motor phases, e.g. U and V atthe terminals of the frequency inverter. The mains-side connection of the frequencyinverter does not affect the sense of rotation of the drive. In addition to checking thedrive, the corresponding actual values and operating messages can be read out bymeans of the control unit.Note:The commissioning of the frequency inverter is complete and can becomplemented by further settings in the PARA menu. The set parametershave been selected in such a way that they are sufficient for commissioningin most applications. The other settings which are relevant tothe application can be checked according to the operating instructions.7.4 Set-up via the Communication InterfaceParameter-setting and commissioning of the frequency inverter via one of the optionalcommunication interfaces include the plausibility check and the parameter identificationfunctions. The parameters can be adjusted by qualified users. The parameterselection during the guided commissioning procedure includes the basic parameters.These are based on standard applications of the corresponding configuration and aretherefore useful for commissioning.Caution!Parameter settings may only be changed by qualified staff. Before startingthe commissioning process, read the documentation carefully and complywith the safety instructions.The parameter SETUP Selection 796 defines the function which is carried out directlyafter the selection (if controller release signal is present at digital input S1IND). Theoperation modes include functions which are also carried out automatically one afterthe other during the guided commissioning procedure.Operation modeFunction0 - Clear Status The auto set-up routine does not perform a function1 - ContinueThe warning message is acknowledged and theauto set-up routine is continued.2 - AbortThe auto set-up routine is stopped and a RESET ofthe frequency inverter is performed.The auto set-up routine is performed in data set 010 - Complete Setup, DS0 and the parameter values are stored in all of thefour data sets identically.11 - Complete Setup, DS1The parameter values of the auto set-up are storedin data set 1.12 - Complete Setup, DS2The parameter values of the auto set-up are storedin data set 2.13 - Complete Setup, DS3The parameter values of the auto set-up are storedin data set 3.14 - Complete Setup, DS4The parameter values of the auto set-up are storedin data set 4.20 - Check Machine Data, DS0The auto set-up routine checks the rated motorparameters in the four data sets.21 - Check Machine Data, DS1The rated motor parameters in data set 1 arechecked for plausibility.22 - Check Machine Data, DS2The rated motor parameters in data set 2 arechecked for plausibility.23 - Check Machine Data, DS3The rated motor parameters in data set 3 arechecked for plausibility.Table "Operation modes for set up" continued on next page.02/06 71

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!