12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

19 Error ProtocolThe various control methods and the hardware of the frequency inverter include functionswhich continuously monitor the application. The operational and error diagnosisis facilitated by the information stored in the error protocol.19.1 Error ListThe last 16 fault messages are stored in chronological order and the No. of Errors362 shows the number of errors which have occurred since commissioning of thefrequency inverter. In the VAL menu branch of the control unit, the error code FXXXXis displayed. The meaning of the error key is described in the following chapter "ErrorMessages". Via the PC program, the number of operation hours (h), operation minutes(m) and the fault message can additionally be read out. The current operating hourscan be read out via the Operation Hours Counter 245. The fault report can be acknowledgedvia the keys of the operating unit and according to the assignment ErrorAcknowledgment 103.Error ListNo. Description Function310 Last Error hhhhh:mm ; FXXXX fault message311 Last Error but one hhhhh:mm ; FXXXX fault message312 to 325 error 3 to error 16362 No. of errors occurredNumber of errors occurred after commissioningof the frequency inverterThe error and warning behavior of the frequency inverter can be set in various ways.The automatic error acknowledgment enables acknowledgment of the faults OvercurrentF0500, Overcurrent F0507 and Overvoltage F0700 without intervention by anoverriding control system or the user. The No. of self acknowledged Errors 363shows the total number of automatic error acknowledgments.Error ListNo. Description Function363 No. of acknowledgmentErrorsTotal number of automatic error acknowledgmentwith synchronization19.1.1 Error MessagesThe error code stored following a fault comprises the error group FXX and the followingcode number XX.Error MessagesCodeMeaningF00 00 No fault has occurred.OverloadF01 00 <strong>Frequency</strong> inverter overloadedF0102 <strong>Frequency</strong> inverter overloaded (60 s), check load behavior03 Short-term overload (1 s), check motor and application parametersHeat SinkF0200 Heat sink temperature too high, check cooling and fan01 Temperature sensor defective or ambient temperature too lowTable "Error Messages" continued on next page.176 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!