12.07.2015 Views

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

Operating Instruction - Frequency Inverter 230V / 400V ... - opis.cz

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5.6.2.2 Configuration 111 – Sensorless Controlwith Technology ControllerConfiguration 111 extends the functionality of the sensorless control by software functionsfor easier adaptation to the customer's requirements in different applications.The Technology Controller enables flow rate, pressure, level or speed control.M-+-V++-X210A1 +20 V/180 mA2 GND 20 V3 S1IND4 S2IND5 S3IND6 S4IND7 S5INDX210BS6IND1234567GND 20 VS1OUTMFO1A+10 V/4 mAMFI1AGND 10 VControl terminal X210AX210A.1 Supply voltage +20VX210A.2 Ground 20 VX210A.3 Controller release / error acknowledgmentX210A.4 Fixed percentage valuechange-over 1X210A.5 Fixed percentage valuechange-over 2X210A.6 Data set change-over 1X210A.7 Data set change-over 2Control terminal X210BX210B.1 Motor thermal contactX210B.2 Ground 20 VX210B.3 <strong>Operating</strong> messageX210B.4 Analog signal of actual frequencyX210B.5 Supply voltage +10VX210B.6 Actual percentage value 0 ...+10 VX210B.7 Ground 10 V5.6.2.3 Configuration 410 – Sensorless Field-Oriented ControlConfiguration 410 contains the functions for sensorless, field-oriented control of a 3-phase machine. The current motor speed is determined from the present currents andvoltages in combination with the machine parameters. Separate control of torque andflux-forming current enables a high drive dynamism at a high load moment.M-+-V+X210A1 +20 V/180 mA2 GND 20 V3 S1IND4 S2IND5 S3IND6 S4IND7 S5INDX210BS6IND1234567GND 20 VS1OUTMFO1A+10 V/4 mAMFI1AGND 10 VControl terminal X210AX210A.1 Supply voltage +20VX210A.2 Ground 20 VX210A.3 Controller release / error acknowledgmentX210A.4 Start of clockwise operationX210A.5 Start of anticlockwise operationX210A.6 Data set change-over 1X210A.7 Data set change-over 2Control terminal X210BX210B.1 Motor thermal contactX210B.2 Ground 20 VX210B.3 <strong>Operating</strong> messageX210B.4 Analog signal of actual frequencyX210B.5 Supply voltage +10VReference value potentiometerX210B.6 Reference speed 0 ...+10 VX210B.7 Ground 10 V02/06 45

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!