If the mains failure with or without shutdown takes so long that the frequency invertershuts off completely (LEDs = OFF), the frequency inverter will be in the"Standby" state when the mains supply is restored. If the inverter is released again,the drive will start. If the drive is to start automatically after restoration of the mainssupply and if the inverter is released permanently, Operation Mode 651 of Auto Startmust be switched on.ParameterSettingsNo. Description Min. Max. Fact. sett.675 Shutdown Threshold 0.00 Hz 999.99 Hz 0.00 Hz676 Reference Shutdown Value Ud min +25 V Ud max -25 V UdThe voltage controller uses the limit values of the DC link voltage. The frequencychange necessary for this is parameterized by the generator reference current valueor rather the ramp. The Gen. Ref. Current Limit 683 or the ramp Mains Support Deceleration673 defines the maximum deceleration of the drive necessary in order toreach the voltage value Reference Mains Support Value 672. The Acceleration onMains Resumption 674 replaces the set values of the ramp parameters Acceleration(Clockwise) 420 or Acceleration Anticlockwise 422 if the value set in the factory ischanged. The voltage control in a mains failure changes from the frequency limitShutdown Threshold 675 from Reference Mains Support Value 672 to the ReferenceShutdown Value 676.ParameterSettingsNo. Description Min. Max. Fact. sett.683 Gen. Ref. Current Limit 0.0 A o ⋅ I FIN I FIN673 Mains Support Deceleration 0.01 Hz/s 9999.99 Hz/s 50.00 Hz/s674 Acceleration on Mains Resumption 0.00 Hz/s 9999.99 Hz/s 0.00 Hz/sThe proportional and integrating part of the current controller can be set via parametersAmplification 677 and Integral Time 678. The control functions are deactivatedby setting the parameters to 0. The controllers are P and I controllers in the correspondingsettings.ParameterSettingsNo. Description Min. Max. Fact. sett.677 Amplification 0.00 30.00 - 1)678 Integral Time 0 ms 10000 ms - 1)1)The factory settings are depending on the selected control function. Correspondingwith the setting of the parameter Configuration 30 the following values are assigned:Configuration 1xx: Amplification 677 = 1,0 / Integral Time 678 = 8 msConfiguration 4xx; 2xx: Amplification 677 = 2,0 / Integral Time 678 = 23 ms148 02/06

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!