Error MessagesCode Message MeaningSF0001Rated currenttoo low low. Correct the value.The value entered for parameter Rated current 371 is tooSF0002Rated currenttoohighThe value for parameter Rated current 371 is too high, referredto parameters Rated power 376 and Rated voltage370. Correct the values.SF0003Rated Cos The value entered for parameter Rated cos phi 374 is wrongPhi(greater than 1 or smaller than 0.3). Correct the value.SF0004SF0005SF0006SF0007Negative slipfrequencySlipfrequencytoo largeOutputbalanceConfig. notsupportedThe calculated slip frequency is negative. Check and, if necessary,correct the values entered for parameters Ratedspeed 372 and Rated frequency 375.The calculated slip frequency is too high. Check and, if necessary,correct the values entered for parameters Ratedspeed 372 and Rated frequency 375.The calculated total output of the drive is lower than therated power. Correct and check, if necessary, the value enteredfor parameter Rated power 376.The set configuration is not supported by the auto set-uproutine.8 <strong>Inverter</strong> DataThe series ACT frequency inverters are suited for a wide range of applications. Themodular hardware and software structure enables customer-specific adaptation. Theavailable hardware functionality of the frequency inverter is displayed in the controlunit and the optional control software VPlus. The software parameters can be adjustedto meet the requirements of the specific application.8.1 Serial NumberThe Serial Number 0 is entered on the nameplate during the fabrication of the frequencyinverter. Information on the device type and the fabrication data (8-digitnumber) are indicated. Additionally, the serial number is printed on the nameplate.Serial number 0 : ACT 401 – 09 ; 04102013Nameplate: Type: ACT 401 – 09 ; Serial No.: 041020138.2 Optional ModulesModular extension of the hardware is possible via the plug-in slots. The Optionalmodules 1 detected by the frequency inverter and the corresponding designations ofthe modules are displayed on the control unit and in the optional control softwareVPlus after initialization. For the parameters required for the extension module, referto the corresponding operating instructions.CM-232 ; EM-SYS02/06 73

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!