Logic discriminationUseOperating principleThis function is used to obtain:c full tripping discrimination,c a substantial reduction in delayed tripping of thecircuit breakers located nearest to the source(drawback of the classical time-based discriminationfunction).This system applies to the definite time (DT) <strong>and</strong> IDMT(st<strong>and</strong>ard inverse time SIT, very inverse time VIT,extremely inverse time EIT <strong>and</strong> ultra inverse time UIT)phase overcurrent <strong>and</strong> earth fault protections.level "n + 1"<strong>Sepam</strong>BI transmissionO14outputs O14otherlevel "n"<strong>Sepam</strong>slevel "n"<strong>Sepam</strong>I12-+O14I12td: X+0.9 sBI receipttd: X+0.6 sRadial distribution with use of time-based discrimination(td: tripping time, definite time curves).td: Xstd: X+0.3 std: Xstd: X sWhen a fault occurs in a radial network, the fault current flows through the circuitbetween the source <strong>and</strong> the location of the fault:c the protections upstream from the fault are triggered,c the protections downstream from the fault are not triggered,c only the first protection upstream from the fault should trip.Each <strong>Sepam</strong> 2000 is capable of transmitting <strong>and</strong> receiving blocking input (BI) ordersexcept for motor <strong>and</strong> capacitor <strong>Sepam</strong>s which can only transmit blocking inputorders.When a <strong>Sepam</strong> 2000 is triggered by a fault current:c It transmits a blocking input order from output O14,c It trips the associated circuit breaker if it does not receive a blocking input order oninput I12.Transmission of the blocking input lasts for the time required to clear the fault. It isinterrupted after a time delay that takes into account the breaking device operatingtime <strong>and</strong> the protection returning time.<strong>Sepam</strong> 2000 includes several phase overcurrent <strong>and</strong> earth fault protection itemswhich provide multi-level protection (low set, high set,...).All the items (set points 1 to 4)* are capable of transmitting blocking inputs.The 2 items, set points 1 <strong>and</strong> 2, do not involve the receipt of a blocking input order<strong>and</strong> are designed for use with time-based discrimination.The 2 items, set points 3 <strong>and</strong> 4, involve the receipt of a blocking input <strong>and</strong> providefast selective operation.This system makes it possible to minimize the duration of the fault, optimizediscrimination <strong>and</strong> guarantee safety in downgraded situations(wiring or switchgear failures).td: Xs(*) Motor <strong>and</strong> capacitor <strong>Sepam</strong> 2000 include two items (set points 1 <strong>and</strong> 2).They do not involve the receipt of blocking inputs since they are designed for loads.Bl ordertd: XsRadial distribution with use of the <strong>Sepam</strong> 2000 logicdiscrimination system.With this type of system, the time delays should be setwith respect to the element to be protected withoutconsidering the discrimination aspect.1/16 Control <strong>and</strong> monitoring functions

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!