13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

display function ANSI pocket parameters comm<strong>and</strong>s setting limitsmessagesterminalitemTHERMAL thermal overload 49 F431 OL1 alarm setting numeric keys 50% to 200%(or hot state) <strong>and</strong> <strong>units</strong>OL2 tripping numeric keys 50% to 200%setting<strong>and</strong> <strong>units</strong>Adjust unbalance data + <strong>and</strong> - keys without = 0, low = 2.25factor average = 4.5, high = 9T1 heat rise numeric keys 5 to 120 mntime constant <strong>and</strong> <strong>units</strong>T2 cooling numeric keys 5 to 600 mntime constant <strong>and</strong> <strong>units</strong>Heating heat rise meteringSYN CHECK synchronism 25 F171 dUs voltage variance numeric keys 0.03 to 0.3Uncheck F181 setting <strong>and</strong> <strong>units</strong>dFs frequency variancenumeric keys 0.05 to 0.5 Hzsetting<strong>and</strong> <strong>units</strong>dPhi phase variance numeric keys 5 to 45 degreessetting<strong>and</strong> <strong>units</strong>Us high setting numeric keys 0.8 to 1.1 Un<strong>and</strong> <strong>units</strong>Us low setting numeric keys 0.1 to 0.7 Un<strong>and</strong> <strong>units</strong>mode operating data + <strong>and</strong> - keys mode 1 to 4modedPhi phase shift meteringvalueUsync1 voltage metering<strong>and</strong> Usync2 valuesREF restricted 64REF F641 Iso setting numeric keys 0.05 to 0.8 Inearth fault F651 <strong>and</strong> <strong>units</strong>F661BREAKER protection 50BF-62 F981 Is setting numeric keys 0.2 to 2 InFAILURE against <strong>and</strong> <strong>units</strong>circuit breaker T1 faulty CB numeric keys 0.05 to 65.5 sfailures retripping <strong>and</strong> <strong>units</strong>time delayT2 adjacent CB numeric keys 0.05 to 65.5 sretripping <strong>and</strong> <strong>units</strong>time delay3-ph I, assignment data + <strong>and</strong> - keys Ioo-I1-I2phase 1 I, of logic inputsI11 to I18phase 2 I, to trip data I21 to I28 (1)phase 3 I. I31 to I38 (1)UNBAL.ALx percentage 50/51 F111 Is setting numeric keys 3 to 200% In,UNBAL.TRIPx type<strong>and</strong> <strong>units</strong>overcurrentx = capacitornumberF112F121F122F131F132T time delay numeric keys 0.05 to 655 svalue<strong>and</strong> <strong>units</strong>(1)according to the number of ESTOR logic input/output boards.Refer to the document entitled "testing", ref. 3140746, regarding protection testing.For further information on the protection function characteristics, .refer to the document entitled “Metering <strong>and</strong> protection functions”, ref. 3140747.Installation - Use - General characteristics - Testing2/17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!