Commissioning usingTSM 2001 pocket terminalSwitch on the <strong>Sepam</strong>After the <strong>Sepam</strong> starts up, check that thereare no messages on the display unit by pressingthe “alarm” key.Checking modeAll information may be accessed for checkingpurposes without the risk of changing parameters<strong>and</strong> settings.Parameter setting modeThis mode is reserved for commissioning<strong>and</strong> maintenance. The entry of a password isrequired. P\ appears at the top left of the screen (1) .Parameter <strong>and</strong> setting errorsChanging a status parameter may put a protectionsetting outside the tolerance range.<strong>Sepam</strong> detects this problem <strong>and</strong> displays thefollowing message:P\VT ratioprotection settingsout of rangepress clearThe user should then check <strong>and</strong>, if necessary, changethe protection settings.The PROTECTION line blinks until the settings havebeen corrected.Settings out of range.A protection or monitoring value may be out of rangewhen it is set.<strong>Sepam</strong> detects this <strong>and</strong> indicates the permissiblerange of settings.P\Sensor2 F462TS1 out of range0 deg < TS1 < 180 degPress ClearAll the parameters <strong>and</strong> settings are accessible in 3 menus (6) :c general parameters: status menu,c protection: protection menu,c operating parameters: program logic menu.General parametersThe general parameters are accessible in the status menu. They are to be setat the time of commissioning <strong>and</strong> must not be modified during current operation.Status menu parameter chartheading name function comm<strong>and</strong> selectionrated Fn network frequency data + <strong>and</strong> - 50 or 60 Hzfrequencyphase CT In CT rating number adjustable fromratio (st<strong>and</strong>ard values) keys 10 A to 6250 AIb basis current number Ib set to thekeys value of Innumber number of data + <strong>and</strong> - 2 or 3 sensorscurrent sensorsmax dem<strong>and</strong> interval peak dem<strong>and</strong> data + <strong>and</strong> - adjustable: 5, 10,interval integration times 15, 30, 60 mnVT ratio number number of wired VTs data + <strong>and</strong> - V1, V2, V3V1 - V2 - V3Unp rated VT number adjustable fromprimary voltage keys 220 V to 500 kVUns rated VT data + <strong>and</strong> - 100, 110, 115,secondary voltage120 Vpower flow incomer reverses the signs data + <strong>and</strong> - incomersense feeder of power <strong>and</strong> energy feedermeasurementstransducer range EANA board data + <strong>and</strong> - 0-20 mAinput range0-10 mA4-20 mA-10/+10 mAcommuni- speed transmission speed data + <strong>and</strong> - 300, 600, 1200,cation (2) 2400, 4800,9600, 19200,38400 bdsadress <strong>Sepam</strong> station number 1 to 255number in the network keysparity transmission format data + <strong>and</strong> - even, odd,no paritytime synchro type of synchronization data + <strong>and</strong> - via networktagging (2) used via inputsI413 or I501events (3) KTS 1-8 numberto KTS 57-64keysI101-108to I709-716passwordsee lastpage(2)please refer to the document “Jbus communication” ref. 3140751 regarding commissioningof the communication link.(3)8 lines for KTSs, 14 lines for ETOR 1 inputs = time-tagged, 0 = not time-tagged,by default all the events are set to zero.Example: temperature sensor.(1)this mode is automatically removed if no keys are activatedfor about 1 mn, or manually by pressing the Code key.Installation - Use - Sheets2/9

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!