Use - commissioningMaintenance (cont’d)<strong>Sepam</strong> 2000 comprises self-testing <strong>and</strong> self-diagnosisto facilitate installation maintenance.Indicator lamps <strong>and</strong> displaymessagesc Green indicator lamp lit up:Le <strong>Sepam</strong> 2000 est sous tension.c No indicator lamps lit up:there is probably an auxiliary power supply fault.Check the auxiliary power supply <strong>and</strong> CE40 boardconnections <strong>and</strong> perform the lamp test.c Red lamp indicates internal <strong>Sepam</strong> 2000 faults.<strong>Sepam</strong> 2000 continuously performs on-line internaltests. When the test results are negative, <strong>Sepam</strong>automatically runs a series of sequences which resultin either:v automatic reinitialization (minor fault, e.g. transientauxiliary power supply break).<strong>Sepam</strong> 2000 carries out a complete restart sequence.If restart is successful, <strong>Sepam</strong> operates againnormally; during the sequence, all the output relaysare dropped out (1) ,v switching to the fail-safe position (major fault).<strong>Sepam</strong> 2000 goes into the fail-safe position.All the output relays drop out (1 ) in order to avoidinadvertent comm<strong>and</strong>s, <strong>and</strong> the watchdog dropsout as well.The following may cause internal faults:c missing cartridge:v red indicator lamp lit up,v display OFF,v no dialogue with pocket terminal,v no dialogue with communication link,v watchdog dropped out,v switching to fail-safe position.<strong>Sepam</strong> 2000 will not start, lacking a program:this is a major fault,c set-up fault:v red indicator lamp lit up,v red lamp indicates CARTRIDGE,v no dialogue with pocket terminal,v no dialogue with communication link,v the watchdog is dropped out,v switching to fail-safe position.<strong>Sepam</strong> 2000 is shut down: this is a major fault.v on <strong>Sepam</strong>s (S35 LS, LR, KR, KZ) with a date codehigher than 97 xx, the 2 ECM boards are not thesame model; two ref. 3122 288 boards or tworef. 03143179FA boards are required.v The type of cartridge is not compatible withthe <strong>Sepam</strong> model.c hardware fault on cartridge:v red indicator lamps lit up,v display indicates M CARTRIDGE,v no dialogue with pocket terminal,v no dialogue with communication,v the watchdog is dropped out,v switching to fail-safe position.<strong>Sepam</strong> 2000 is shut down: this is a major fault.v the cartridge is faulty,v disconnect the auxiliary power supply,v <strong>Sepam</strong> is automatically out of order until a new cartridge is installed.Consult your maintenance department.c other major faults:v red indicator lit up,v display indicates MAINTENANCE,v no dialogue with the pocket terminal,v no dialogue with the communication link (if the CPU is faulty),v the watchdog is dropped out,v switching to the fail-safe position.<strong>Sepam</strong> 2000 is shut down: this is a major fault.Consult your maintenance department.c minor or partial fault:v red indicator extinguished,v display indicates MAINTENANCE,v dialogue with the pocket terminal is maintained,v dialogue with the communication link is maintained,v the watchdog does not drop out.<strong>Sepam</strong> 2000 is operating, however it has detected a transient fault or a componenthas failed to pass self-testing.Consult your maintenance department.c other minor or partial fault:v red indicator extinguished,v display indicates M CARTRIDGE,v dialogue with the pocket terminal is maintained,v dialogue with communication is maintained,v the watchdog does not drop out again<strong>Sepam</strong> 2000 is operating, but it has detected a fault in the status parameter settingor an overrun of the number of entries written in the cartridge memory(S25/S35 only).Set the status parameters that are blinking or consult your maintenancedepartment.(1)this may cause tripping with undervoltage program logic (so-called fail-safe logic).Caution: do not insert or remove cartridge while <strong>Sepam</strong>is energized.v Disconnect the auxiliary power supply <strong>and</strong> wait2 seconds before h<strong>and</strong>ling the cartridge.Check the references on the <strong>Sepam</strong> <strong>and</strong> on thecartridge (refer to your <strong>Sepam</strong> 2000 identificationchapter).v <strong>Sepam</strong> 2000 is automatically disabled untilthe appropriate cartridge is installed.2/42 Installation - Use - General characteristics - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!