13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Data addresses <strong>and</strong> encoding (cont’d)Control logic zone (cont’d)<strong>control</strong> logic word bit access Jbus function format unit as ofzone address address enabled versionremote <strong>control</strong>KTC1-16 (latched KTC) 0C80 C800- C80F read/write 1, 3, 5, 6, 15, 16 E noneKTC17-32 (latched KTC) 0C81 C810- C81F read/write 1, 3, 5, 6, 15, 16 E nonereserved 0C82-0C87 init. to 0KTC33-48 (impulse KTC) 0C88 C880- C88F read/write 1, 3, 5, 6, 15, 16 E noneKTC49-64 (impulse KTC) 0C89 C890- C89F read/write 1, 3, 5, 6, 15, 16 E noneKTC65-KTC80 (impulse KTC) 0C8A C8A0-C8AF read/write 1, 3, 5, 6, 15, 16 E none 3.1KTC81-KTC96 (impulse KTC) 0C8B C8B0-C8BF read/write 1, 3, 5, 6, 15, 16 E none 3.1remote annunciationreserved 0C8C C8C0- C8CF read 1, 3 init. to 0reserved 0C8D C8D0- C8DF read 1, 3 init. to 0reserved 0C8E C8E0- C8EF read 1, 3 init. to 0<strong>Sepam</strong> check 0C8F C8F0- C8FF read 1, 3, 7(b15-b8) (1) X noneKTS1-KTS16 0C90 C900- C90F read 1, 3 E noneKTS17-KTS32 0C91 C910- C91F read 1, 3 E noneKTS33-KTS48 0C92 C920-C92F read 1, 3 E none 3.1KTS49-KTS64 0C93 C930-C93F read 1, 3 E none 3.1reserved 0C94 C940-C94F read 1, 3 init. to 0reserved 0C95 read 3 init. to 0reserved 0C96 read 3 init. to 0reserved 0C97 read 3 init. to 0KTS1-KTS16 (oscill. status) 0C98 C980- C98F read 1, 3 E noneKTS17-KTS32 (oscill. status) 0C99 C990- C99F read 1, 3 E noneKTS33-KTS48 (oscill. status) 0C9A C9A0-C9AF read 1, 3 E none 3.1KTS49-KTS64 (oscill. status) 0C9B C9B0-C9BF read 1, 3 E none 3.1reserved 0C9C-0C9F C9C0-C9FF read 1, 3 init. to 0event countersC1 0C40 read 3 A noneC2 0C41 read 3 A noneC3 0C42 read 3 A noneC4 0C43 read 3 A noneC5 0C44 read 3 A noneC6 0C45 read 3 A noneC7 0C46 read 3 A noneC8 0C47 read 3 A noneC9 0C48 read 3 A noneC10 0C49 read 3 A noneC11 0C4A read 3 A noneC12 0C4B read 3 A noneC13 0C4C read 3 A noneC14 0C4D read 3 A noneC15 0C4E read 3 A noneC16 0C4F read 3 A noneC17 0C50 read 3 A none 3.1C18 0C51 read 3 A none 3.1C19 0C52 read 3 A none 3.1C20 0C53 read 3 A none 3.1C21 0C54 read 3 A none 3.1C22 0C55 read 3 A none 3.1C23 0C56 read 3 A none 3.1C24 0C57 read 3 A none 3.1(1)Jbus/Modbus function n° 7 “high-speed 8 bit reading” can be used to read the value of the most significant byte of the “<strong>Sepam</strong> check” word, with Jbus address0C8F (refer to the appendix which describes Jbus protocol).10 Jbus/Modbus communication

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!