13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

TEST SHEET <strong>Sepam</strong> 2000Project : ....................................................................................................Switchboard: .........................................................................................Type of <strong>Sepam</strong> 2000Panel: ........................................................................................................serial number.......................................................................................................................Commissioning testsCheck current <strong>and</strong> voltage sensor wiring <strong>and</strong> phase rotation order beforeh<strong>and</strong>.Set the status parameters <strong>and</strong> set the protections according to the setting record sheet.type of test scheme result display<strong>Sepam</strong> connected to current sensors only (1)secondary injection I1 = 1 or 5 A B6 primary rated I1 = ................................of rated current I2 = 1 or 5 A current I2 = ................................I3 = 1 or 5 A I3 = ................................<strong>Sepam</strong> connected to current <strong>and</strong> voltage sensors(1)see “Testing” documentation3-phase secondary rated current B6 P=+ 3Un.InP = + ............................. feeder2injection (1 or 5 A)rated voltage Q=+3Un.InQ = + .............................2(Uns)phase shift ϕ = -30° P=- 3Un.InP = - ............................. incomer2inductive3Un.InQ=-Q = -.............................2residual current according to assemblySum 3I3-phase secondaryrated currentinjection (1 or 5 A) residual I = 0 Ir =in 1 phase rated current residual I = rated I Ir =(1 or 5 A)CSHprimary injection 30 A 28.5 ≤ residual I ≤ 31.5 A Ir =primary injection 0.2 A 0.18 ≤ residual I ≤ 0.22 A Ir =B6B7................................................................................................................................CT (with CSH 30 or ACE 990)B7secondary injection(with CSH 30) rated current (1 or 5 A) residual I = rated I Ir = ................................primary injectionresidual I = injected currentresidual voltage according to assemblyVT in broken deltaB7single-phase Unsresidual voltage Vo = ..............................secondary injection3= phase voltageVT in starB63-phase secondary Unsresidual voltage Vo = ..............................injection3= phase voltagelogic input / output wiringcheck the conformity of logic input <strong>and</strong> output connectioncircuit breaker/contactor program logicclosing by closing button closing of device<strong>control</strong>tripping by tripping button opening of device<strong>control</strong>pilot wire test (st<strong>and</strong>ard <strong>Sepam</strong>)test the link (KP18)(message) RECEIVE.BI(on upstream <strong>Sepam</strong>)Tests carried out on:by:Comments:SignatureSignatureInstallation - Use - General characteristics - Testing4/3

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!