Reading of diagnosiscounters: function 8Each <strong>Sepam</strong> 2000 is assigned event counters(or diagnosis counters). In all, there are 8 countersper <strong>Sepam</strong> 2000.The counters are 16-bit words. In the chart opposite,the value of data XXXX is equal to:c 0000 for the request,c the content of the counter concerned for the reply.If the counters reach FFFF, they automatically switchto 0000.Request / replyslavenumber8sub-functioncodesub-function datacodesthe <strong>Sepam</strong> 2000 must send the echo 0000 XYZT (1)of the requestrreset to zero of the diagnosis counters 000A 0000reading of the total number of:frames received with no CRC error (CPT1) 000B XXXXframes received with a CRC error (CPT2) 000C XXXXexception replies (CPT3) 000D XXXXframes addressed to <strong>Sepam</strong> 2000 (CPT4) 000E XXXX(excluding broadcasting)broadcasting requests received (CPT5) 000F XXXXexception replies(including broadcasting (CPT6 / function 13) 0010 XXXX<strong>Sepam</strong> 2000 not ready replies (CPT7) 0011 XXXXcharacters not processed (CPT8) 0012 XXXX(1)X, Y, Z, T set by the user (for transmission checking).dataCRC 161 byte 1 byte2 bytes 2 bytes2 bytesReading of event counter:function 11Each <strong>Sepam</strong> 2000 has an event counter (CPT9).The counter is incremented each time a frameis correctly received <strong>and</strong> interpreted by the slave(except for the specific counter reading com<strong>and</strong>:function 11). A correct broadcasting comm<strong>and</strong>increments the counter. If the slave transmitsan exception reply, the counter is not incremented.The counter makes it possible to find out fromthe master whether the <strong>Sepam</strong> 2000 has correctlyinterpreted the comm<strong>and</strong> (event counter incremented)or not interpreted if (counter not incremented).Reading of the different elements makes it possibleto diagnose the exchanges that have taken placebetween the master <strong>and</strong> the <strong>Sepam</strong> 2000.If the master counter = the <strong>Sepam</strong> 2000 counter,the comm<strong>and</strong> sent by the master has been executed.If the master counter = the slave counter + 1, thecomm<strong>and</strong> sent by the master has not been executed.RequestslavenumberReply0BCRC 161 byte 1 byte2 bytesslavenumber0B0slave countercontentPlease refer to the «implementation» chapter, «diagnosis counter» section.CRC 161 byte 1 byte 2 bytes 2 bytes2 bytesJbus/Modbus communication43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!