Events zoneThe events zone is a table which contains a maximum of 4 time tagged eventsavailable via Jbus communication.Events should be read in a single block containing 33 words using Jbus function 3.The exchange word can be written using Jbus functions 6 or 16, <strong>and</strong> readindividually using Jbus function 3.events zone word access Jbus functionaddressenabledexchange word 0040 read/write 3,6,16event n° 1 0041-0048 read 3event n° 2 0049-0050 read 3event n° 3 0051-0058 read 3event n° 4 0059-0060 read 3See “time tagging of events” chapter for data format.Grouping zoneThe grouping zone (version 4.0 <strong>and</strong> higher) contains the main <strong>Sepam</strong> 2000 datain a single table of 125 words. The table may be read:c totally (125 words) via a single query,c or by zone via one or more queries. The KTCs may be accessed in reading modefrom the 0105 to 010A or 0C80 to 0C8B addresses.grouping zone word bit access Jbus function format valueaddress address authorized<strong>Sepam</strong> check word 0100 read 3 X noneKTS1-KTS16 (status) 0101 read 3 E noneKTS17-KTS32 (status) 0102 read 3 E noneKTS33-KTS48 (status) 0103 read 3 E noneKTS49-KTS64 (status) 0104 read 3 E noneKTC1-KTC16 (KTCM) 0105 1050/5F read/write 1/5/3/15/6/16 E noneKTC17-KTC32 (KTCM) 0106 1060/6F read/write 1/5/3/15/6/16 E noneKTC33-KTC48 (KTCI) 0107 1070/7F read/write 1/5/3/15/6/16 E noneKTC49-KTC64 (KTCI) 0108 1080/8F read/write 1/5/3/15/6/16 E noneKTC65-KTC80 (KTCI) 0109 1090/9F read/write 1/5/3/15/6/16 E noneKTC81-KTC96 (KTCI) 010A 10A0/AF read/write 1/5/3/15/6/16 E nonereserved 010B/010F read 3 0I1-I2 + oscillating status 0110 read 3 E noneI11-I18 + oscillating status 0111 read 3 E noneI21-I28 + oscillating status 0112 read 3 E noneI31-I38 + oscillating status 0113 read 3 E noneI1 0114 read 3 A 0.1 AI2 0115 read 3 A 0.1 AI3 0116 read 3 A 0.1 AIo 0117 read 3 A 0.1 Athermal cap. used 0118 read 3 A 0.1 Areserved 0119 read 3starts per hour (if > 0) 011A read 3 B 1 starttime before start (if < 0)1 mnreserved 011B read 3 0U21 011C read 3 A 10 VU32 011D read 3 A 10 VU13 011E read 3 A 10 VV1 011F read 3 A 10 VV2 0120 read 3 A 10 VV3 0121 read 3 A 10 VVo 0122 read 3 A 1 VF 0123 read 3 A 0.01 Hzpower factor 0124 read 3 C 0.01P 0125 read 3 B 1 kWP 0126 read 3 B 10 kWQ 0127 read 3 B 1 kVArQ 0128 read 3 B 10 kVArI1’ 0129 read 3 A 0.1 AI2’ 012A read 3 A 0.1 AI3’ 012B read 3 A 0.1 AU21’ 012C read 3 A 10 VU32’ 012D read 3 A 10 VU13’ 012E read 3 A 10 Vreserved 012F/0133 read 3 0Jbus/Modbus communication7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!