13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SETTING RECORD SHEETProject: .....................................................................................................Switchboard: .........................................................................................Panel: ...............................................................................................................................................................................................................................Status menu parameterMenu Name FunctionFrequency Fn Network frequency 50 Hz 60 HzTC,TC',TC" phase In CT rating (in Amps)board 2 winding 1 board 3 winding 2 board 4 winding 3Io sensor Ino Residual current Sum 3l Sum 3l Sum 3lI'o sensor measurement Core bal. 2A Core bal.2A Core bal. 2AI''o sensor Core bal. 30A Core bal.30A Core bal. 30ACT + CSH30 CT + CSH30 CT + CSH30A kA A kA A kAcore bal. CT + ACE990 core bal. CT + ACE990 core bal. CT + ACE990A kA A kA A kATransformer index' vector group compared toindex" winding 1S powerUn, Un',Un" rated voltage<strong>Sepam</strong> 2000 differentialType of <strong>Sepam</strong> 2000serial numberDisturbance pretrig number of periodsrecording before triggering event periodsCommuni- Address <strong>Sepam</strong> station numbercationin networkBauds transmission speed 300 600 1200 2400(Jbus/Modbus) 4800 9600 19200 38400Parity transmission format even odd no parity(Jbus/Modbus)Time tagging Synchro Type of synchronization via network via input I11usedvia input I21MicroswitchECMD current boardsettingsPut an X in a box toindicate switchsettinge.g. switch set to rightSW2SW2SW2XSW1SW1SW1Program logic parametersKP 0 or 1KP1winding 1 breaker: undervolt. trip coilKP2winding 2 breaker: undervolt. trip coilKP3winding 3 breaker: undervolt. trip coilKP5I15, I16, I17, I18 for normallyclosed contact (NC)KP7I1, I2 for normallyclosed contact (NC)KP8I13, I14 for normallyclosed contactKP10 I2, I14 for tripping winding 1 <strong>and</strong> 2KP13 latching outputsKP38 remote setting disableTime delay (value)T1impulse O1 <strong>and</strong> O12T2impulse O2 <strong>and</strong> O13D21 - D22 - D31 - Setting record sheet - test sheetKP 0 or 1 impulse D21 D31D22KP50 disturbance recordinginhibitionKP51 automatic trippingof disturbance recordingKP50 disturbance recordinginhibition<strong>Protection</strong> setting recordDifférentialId/It % percentage set pointrestricted earth fault, winding 2IsoAmps set pointrestricted earth fault, winding 3IsoAmps set point4/11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!