13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Sepam</strong> 2000 componentsslot 6 5 4 3 2 1ESTOR2 (1) ESTOR1 ESB ECM (2) CE40S26 model*XT ESTOR ESTOR ESB 3U/VoLX ESTOR (4) ESTOR (4) ESB_LT ESTOR (4) ESTOR (4) ESB 3U/Vo ECM CE40LS ESTOR ESTOR ESB SONDE ECM CE40slot 8 7 6 5 4 3 2 1ESTOR2 (1) (3) ESTOR1 ESB 3U/Vo ECM (2) CE40S36 model*XR ESTOR ESTOR ESTOR ESB 3U/VoLR ESTOR ESTOR ESTOR ESB 3U/Vo ECM ECM CE40LS SONDE ESTOR ESTOR ESB 3U/Vo ECM ECM CE40SS SONDE ESTOR ESTOR ESB 3U/Vo SONDE ECM CE40SR ESTOR ESTOR ESTOR ESB 3U/Vo SONDE ECM CE40KR ESTOR ESTOR ESTOR ESB_ECM ECM CE40KZ SONDE ESTOR ESTOR ESB_ECM ECM CE40YR ESTOR ESTOR ESTOR ESB__ECM CE40ZR ESTOR ESTOR ESTOR ESB_SONDE ECM CE40TR ESTOR ESTOR ESTOR ESB 3U/Vo 3U/Vo ECM CE40TS SONDE ESTOR ESTOR ESB 3U/Vo 3U/Vo ECM CE40CR ESTOR (5) ESTOR (5) ESTOR ESB_ECMD ECMD CE40CC ESTOR ESTOR ESTOR ESB ECMD ECMD ECMD CE40(1)the ESTOR board may be installed, depending on the application,(2)or ECA for CSP sensors(3)option for ESTOR board(4)for SX1 <strong>and</strong> SX2 applications ESTOR boards are not installed.(5)except for S35 CR.__ECMECMCE40CE40CE40Connection principleThe <strong>Sepam</strong> 2000 connections are made on the removable connectors locatedon the rear of the device. All the connectors are screw-lockable.Wiring of screw connectors:c recommended wire fitting:v Telemecanique DZ5CE0155 for 1.5 mm 2 ,v DZ5CE0253 for 2.5 mm 2 .Stripped length with fitting: 17 mm.Without fitting:c stripped length: 10 to 12 mm,c maximum 2 wires per terminal.The 21-pin connectors must be connected correctly by h<strong>and</strong> before being lockedby the 2 screws (top/bottom).SONDE ESTOR ESTOR ESB 3U/V0 SONDE212019181716151413121110987654321A8PROBES212019181716151413121110987654321A24-30 48-125 220-250V-DC7INPUTS ANDOUTPUTS212120201919181817171616151514141313121211111010998877665544332211AA65INPUTS AND INPUTS ANDOUTPUTS OUTPUTS* S25, S35 for earlier versions.24-30 48-125 220-250V-DC24-30 48-125 220-250V-DC87654321ASW14VOLTAGEINPUT212019181716151413121110987654321A3PROBESECMBSW2SW1B654321A2CURRENTINPUT43 +21ACE40B24-30 48-125 220-250V-DC1POWER SUPPLY(communicationoption)All the <strong>Sepam</strong> 2000 connection terminals are located on the rear of the device.The <strong>Sepam</strong> 2000 boards are fitted into numbered slots on the back;<strong>Sepam</strong> S26*: 1 to 6,<strong>Sepam</strong> S36*: 1 to 8.The connections are identified by adding different markings:c slots 1 to 8,c connectors A or B,c terminals 1 to 21.Example: 5 A16slot n° 5, connector A, terminal 16.Each connector is used for a specific functionalunit identified in the top right-h<strong>and</strong> corner according to the function:c CE40: auxiliary supply <strong>and</strong> communication option,c ECM: current sensor (CT) interface,c ECA: current sensor (CSP) interface,c 3U/Vo: voltage sensor interface,c ESB: circuit breaker <strong>control</strong> interface,c ESTOR: auxiliary <strong>control</strong> circuit interface,c SONDE: Pt100 temperature sensor interface.The relative position of the <strong>units</strong> depends on the <strong>Sepam</strong> 2000 model.Installation - Use - General characteristics - Testing1/7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!