13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SETTING RECORD SHEETProject: .....................................................................................................Switchboard: .........................................................................................Panel: ...............................................................................................................................................................................................................................<strong>Sepam</strong> 2000 SubstationType of <strong>Sepam</strong> 2000 Sserial numberStatus menu parametersmenu name functionfrequency Fn network frequency 50 Hz 60 Hzphase CTboard 2 (ECM or ECA)ratio In CT rating or CSP (in Amps) A kAIb basis current (in Amps) A kAnumber number of current sensors I1-I3 I1-I2-I3Io sensorboard 2 (ECM or ECA)Ino residual current Sum 3I for CTmeasurement Sum1 3I or Sum2 3I for CSP2 A core bal. CT 30 A core bal. CTCT + CSH 30 for S26, S36AkAAkA for S25, S35core bal. CT + ACE 990AkAmax. dem<strong>and</strong> interval max. dem<strong>and</strong> 5 mn 10 mn 15 mn 30 mninterval integration time 60 mnVT ratio number number of wired VTs V 1U 3U S26, S36U21 U21-U32 3U S25, S35Unp rated VT voltsprimary voltage kilovoltsUns rated VT 100 V 110 V 115 V 120 Vsecondary voltageVnso type of residual voltage Sum 3V Uns/ 3 Uns/3measurementpower flow incomer reverses the signs of power Incomer = cables to busbarsdirection feeder <strong>and</strong> energy measurements Feeder = busbars to cablesdisturbance pretrig number of periodsrecordingbefore triggering event of thedisturbance recordingperiodscommuni- bauds transmission speed 300 600 1200 2400cation 4800 9600 19200 38400address <strong>Sepam</strong> station numberin networkparity transmission format even odd no paritytime tagging synchro type of synchronization via network via input I11used via input I21events KTS1 to 8KTS9 to 16N.B. KTS17 to 24For each event, KTS25 to 32choose 0 or 1 KTS33 to 400 = not time-tagged KTS41 to 481 = time-tagged KTS49 to 56all events are set KTS57 to 64to 0 by defaultI1 I2I11 to I18KTS33 to 64 for S26, S36 I21 to I28onlyI31 to I38<strong>Sepam</strong> 2000 - Testing3/5

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!