InstallationUse <strong>and</strong> connection of CSH 120 <strong>and</strong> CSH 200 core balance CTsCSH 120 <strong>and</strong> CSH 200core balance CTsThe specific CSH 120 <strong>and</strong> CSH 200 core balanceCTs are used for direct measurement of earth faultcurrent. The only difference between them is theirinner diameter <strong>and</strong> they operate with 2 input ratings:c 2 A input rating:settings from 0.1 A to 20 A,c 30 A input rating:settings from 1.5 to 300 A.Due to the CSHs’ low voltage isolation,they may only be used on cables.300 A100 A80 A50 ACSH 20030 A corebalanceCSH 120 CT ratingI mm2 Ω 10 ΩCharacteristics:c inner diameter:v CSH 120 : ø 120 mm,v CSH 200 : ø 200 mm.c accuracy: ±5%,c transformer ratio: 1/470,c maximum permissible current: 20kA-1 second,c operating temperature: - 25 °C to +70 °C,c storage temperature: - 40 °C to +85 °C,c maximum metering current I mm.This is a current value beyond which the <strong>Sepam</strong>CSH core balance assembly saturates.The user must therefore be careful not to set thetripping threshold higher than I mm.The maximum metering current depends on:v chosen rating (2 A or 30 A core balance CT),v core balance CT used (CSH 120 or CSH 200),v wiring resistance Rw back <strong>and</strong> forth between thecore balance CT <strong>and</strong> <strong>Sepam</strong> 2000.20 A0.1 Ω 1 ΩCSH 120CSH 200R W2 A corebalanceCT ratingThe graph above gives the value of I mmfor Rw < 10 Ω.This graph is used to choose the required core balance CT <strong>and</strong> wiring.Example: the high setting of the earth fault protection is 80 A.Therefore, the 30 A rating of <strong>Sepam</strong> 2000 is chosen (wiring to terminals 3 <strong>and</strong> 4of the earth fault connector).From the graph, it may be deduced that the CSH 120 <strong>and</strong> CSH 200 are suitableregardless of the wiring resistance, within the limit of 10 Ω.Dø 5 mountingCFHø AGKBSelection of operating mode(microswitches)c Set the SW1 microswitches on the <strong>Sepam</strong> 2000.The microswitches concerned are found on the inputmodule. They should be switched while the <strong>Sepam</strong>2000 is de-energized.The microswitches are hidden by the CCA 660 orCCA 650 connector once it has been installed.JLEdimensions (mm)weight (kg)A B C D E F G H J K LCSH 120120 164 26,5 44 190 76 52 40 166 62 35 0.6CSH 200200 256 28 46 274 120 90 60 257 104 37 1.4SW2SW1for measuring residual currentby a CSH core balance CT.1/16 Installation - Use - General characteristics - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!