13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

InstallationUse conditionsInstallation of <strong>Sepam</strong> 2000Each <strong>Sepam</strong> 2000 comes in a single packagewhich contains:c <strong>Sepam</strong> 2000,c mounting accessories,c connection accessories (connectors).The other optional accessories come in a separatepackage.We recommend that you follow the instructions givenin this document for quick, correct installation of your<strong>Sepam</strong> 2000:c equipment identification,c assembly,c connection of current <strong>and</strong> voltage inputs, probes,c microswitch setting,c connection of power supply <strong>and</strong> earth,c checking prior to commissioning.H<strong>and</strong>ling,transport <strong>and</strong> storage<strong>Sepam</strong> 2000 in its original packagingTransport:<strong>Sepam</strong> 2000 may be shipped to any destinationwithout taking any additional precautions by all usualmeans of transport.H<strong>and</strong>ling:<strong>Sepam</strong> 2000 may be h<strong>and</strong>led without any particularcare <strong>and</strong> can even withst<strong>and</strong> being dropped by aperson h<strong>and</strong>ling it (person st<strong>and</strong>ing on floor).Environment of the installed <strong>Sepam</strong> 2000Operation in a damp environmentThe temperature/relative humidity factors must compatible with the unit’senvironmental withst<strong>and</strong> characteristics.If the use conditions are outside the normal zone, commissioning arrangementsshould be made, such as air conditioning of the premises.T (°C)5540normal use zone35 65 93 95humidity (%)Operation in a polluted atmosphere<strong>Sepam</strong> 2000 is designed to be used in a clean industrial environment as definedby IEC 60654-4 class 1. A contaminated industrial atmosphere components(such as the presence of chlorine, hydrofluoric acid, sulfur, solvents…)may cause corrosion of the electronic components, in which case environmental<strong>control</strong> arrangements should be made (such as closed, pressurized premiseswith filtered air,…) for commissioning.Storage:<strong>Sepam</strong> 2000 may be stored in closed premisesfor several years. Periodic, yearly checkingof the environment <strong>and</strong> the packaging conditionis recommended.<strong>Sepam</strong> 2000 installed in a cubicleTransport:<strong>Sepam</strong> 2000 may be transported by all usual meansof transport in the customary conditions used forcubicles. Storage conditions should be taken intoconsideration for a long period of transport.H<strong>and</strong>ling:Should the <strong>Sepam</strong> 2000 fall out of a cubicle, check itscondition by visual inspection <strong>and</strong> energizing. If thereis any doubt, return the <strong>Sepam</strong> 2000 for checking inthe factory.Storage:Keep the cubicle protection packing for as long aspossible. <strong>Sepam</strong> 2000, like all electronic <strong>units</strong>, shouldnot be stored in a damp environment for more than amonth. <strong>Sepam</strong> 2000 should be energized as quicklyas possible. If this is not possible, the cubiclereheating system should be activated.1/2 Installation - Use - General characteristics - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!