Motor/generator differential protectionANSI codefunction n°87M - 87GF621Equipmentc 2 current generatorsc 2 ammetersc 2 adapters for ECA modulesc "protection function" documentationc calculatorWiringc diagrams B1 <strong>and</strong> B13c protective relays: F621/4Testc read the section entitled measurement <strong>and</strong> testingmethodThis function operates on the 3 phases individually<strong>and</strong> may be tested with single-phase, one phaseat a time.The test calls for the use of two current injection <strong>units</strong>.In order for the measurements to be accurate,the two currents must be in phase.c status parameter settingv check the microswitches on the two ECM or ECAProcedurec <strong>Protection</strong> parameter setting: motor diff or gene diffv set Is as a % of In to the desired value (5% to 50% of In)v disable the following protections (2) :O/Cx, E/Fx (if sum of 3 CTs is used), thermal overload, unbalance, Start Hour,LR/ESttesting of operationv determine the operating point to be tested, i.e :choose the value of It/Inchoose the value of Is/Inv read in the chart which follows the minimum value of Id/In that trips theprotection, with Id/In ≥ 1.2 Is/Inv preset the injections:v inject the two currents IA <strong>and</strong> Id at the same time according to diagram B13,with IA = It - Id 2v check on F621/4 that the function has picked upv cut off the injectionsv press the "reset" button (1) on <strong>Sepam</strong> 2000 to earase the messages <strong>and</strong> make therelay drop out again.c examplev testing the protection for a through- current of In <strong>and</strong> an Is setting of 20% of Inv use the chart to read:for It/In = 1 <strong>and</strong> Is/In = 0.2read the value of Id/In: 0.2669Preset Is = 0.84 In et Id = 0.32 Inv inject the 2 currents at the same timev the relay picks upv press reset (1) on <strong>Sepam</strong> 2000 to erase the message <strong>and</strong> make the relay drop outagain.Testing of tripping timev wire according to diagram B1; use a single current generator (I' = 0)v given I = 1,2 Inv preset I1 to 40 A, i.e. 1 A in the secondary circuitv set the chronometer to zerov start injection <strong>and</strong> the chronometer at the same timev after the chronometer is stopped by the <strong>Sepam</strong> 2000 relay, read the time(about 40 ms)(1)this function may only be activated if your program logichas been customized.(2)remember to reactivate the protections at the end of testing.X = number of the protective relay.1/50<strong>Sepam</strong> 2000 - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!