Setting Adjust = None does not take into account the unbalance value <strong>and</strong> doesnot allow single-phase injection to be used.c example: heat riseCase of an unbalanced motor. Use of diagram B9.In = 400 AIb = 280 AI1, I2, I3v set OL1 = 95%v set OL2 = 115%v set T1 = 5 mnv set T2 = 20 mnv set Adjust = High (= 9)v Heating = 0%The equivalent current value should be calculated so as to enable the user toselect the right I/Ib ratio in the chart that gives t/T1 for f(OL, I/Ib).In the example i = 1.3 Ibieq 2 = (Ib+30%Ib) 2 + 9([Ib+30%Ib] / 1.732) 2i.e. ieq 2 = 364 2 + 9(210) 2 fi ieq = 728 Ahence I/Ib = 728 A/280 A = 2.6For an injection i = 364 A, in accordance with diagram B9 or B10, the protectionwill trip OL1 in a time period of t1 = 0.1514 x 5 x 60 = 45 s <strong>and</strong> OL2 in a timeperiod of t2 = 0.1865 x 5 x 60 = 55.9 sMonitor Heating the variation in heat rise Heating on the pocket terminal.Hot curvev reach Heating = 100%v start up injection <strong>and</strong> the chronometer at the same timev monitor the injection value on the ammeter (stability)v use the pocket termial to monitor the variation in heat rise HeatingWhen OL2 is reachedv the <strong>Sepam</strong> 2000 output relay stops the chronometerv read the t value measured by the chronometerv stop the injectionv press reset (1) on <strong>Sepam</strong> 2000 to erase the messages <strong>and</strong> reset the relay(if Heating > OL).Practical method of protection time measurement <strong>and</strong> testing using initialheat risev set OL2 to the initial heat rise value Eiv reset heat rise to zero using the pocket terminal (password + clear)v start up injection <strong>and</strong> the chronometerWhen OL2 = Ei is reachedv the chronmeter indicates the time tiv set OL2 to the desired valuev reset heat rise Heating to zero using the pocket terminal (access code + clear)v start up injection <strong>and</strong> the chronometer.When OL2 is reachedv the chronmeter indicates the time tf.v the protection operating time starting from initial heat rise Ei is t = tf - ti.<strong>Sepam</strong> 2000 - Testing1/19

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!