Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Parameter <strong>and</strong> setting errorsChanging a status parameter may put a protectionsetting outside the tolerance range.<strong>Sepam</strong> detects this problem <strong>and</strong> displays thefollowing message:P\CT ratioprotection settingout of rangepress clear keyThe user should then check <strong>and</strong>, if necessary, changethe protection settings. The PROTECTION line blinksuntil the settings have been corrected.Settings out of range.A protection value may be out of range when it is set..<strong>Sepam</strong> detects this <strong>and</strong> indicates the permissiblerange of settings.P\50N-51N F081Iso out of range0.05Ino < Iso < InoPress clear keyExample: 50N, 51N earth protection.All the parameters <strong>and</strong> settings are accessible in3 menus:v general parameters: status menu,v protection : protection menu,v operating parameters:program logic menu,General parametersThe general parameters are accessiblein the status menu; they are to be set at the timeof commissioning, using the setting sheet(see corresponding chapter) <strong>and</strong> must not bemodified during current operation.Installation - Use - General characteristics - TestingStatus menu parameter chartheading name function comm<strong>and</strong> selectionfrequency Fn network frequency data + <strong>and</strong> - 50 or 60 Hzkeysphase CT In CT rating numeric adjustable fromratio keys 10 A to 6250 Aphase CT' Ib basis current of numeric 0.4 to 1.3Inratio for CT equip. being protected keys in ampsnumber number of current data + <strong>and</strong> - 2 or 3 sensorssensorskeysphase CT In CT rating (st<strong>and</strong>ard data + <strong>and</strong> - 30 values betweenratio for CSP values see table on keys 30 A <strong>and</strong> 2500 Athe next page)Ib basis current of the numeric 0.4In to 1.3Inequipment being protected keys in amperesnumber number of data + <strong>and</strong> - 2 or 3 sensorscurrent sensors keyscapteur Io sensor type of earth data + <strong>and</strong> - c sum of 3Icapteur Io’ fault current keys c 2 A core bal. CTc tore 30 Ac 30 A core bal. CTc core bal. CT+ ACE 990Ino CT rating with CT S26, S36 adjustable from+ CSH 30 option numeric 1.0 A <strong>and</strong> 6250 Akeyscore bal. CT rating with S25, S35 56 values fromcore bal. CT + data + <strong>and</strong> - 1 A to 6250 AACE 990 option keysmax. period max. dem<strong>and</strong> integration data + <strong>and</strong> - adjustable frominterval period keys 5, 10, 15, 30, 60 mnphase VT number number of VTs wirred data + <strong>and</strong> - S26-S36 S25-S35phase VT’ keys V U211U U21-U323U 3UUnp rated VT primary numeric adjustable fromvoltage keys 220 V to 250 kVUns rated VT secondary data + <strong>and</strong> - 100, 110, 115,voltage keys 120 VVnso type of residual data + <strong>and</strong> - c sum of 3Vsvoltage measurement keys c Uns / ec Uns / 3direction of incomer reverses the signs data + <strong>and</strong> - incomer:energy feeder of power <strong>and</strong> energy keys cable --> busbars (1)measurementsfeeder:busbars --> cable (1)disturbance pretrig number of periods numeric adjustable fromrecording (4) before triggering keys 1 <strong>and</strong> 85 periodseventcommuni- speed transmission speed data + <strong>and</strong> - 300, 600, 1200,cation (2) keys 2400, 4800, 9600,19200, 38400 bdsstation <strong>Sepam</strong> station number numeric 1 to 255in the networkkeysparity transmission format data + <strong>and</strong> - even, odd,keys without paritytime synchro type of synchronization data + <strong>and</strong> - via:tagging (2) used keys - network- inputs I11 or I21events I1 I2 numeric(3)I11 to I18keysI21 to I28I31 to I38KTS1 to KTS32 by 8-bit wordsKTS33 to KTS64 for S26, S36onlypasswordsee correspondingpage(1)incomer + , feeder +(2)for commissioning, refer to “communication” document.(3)0 = not time-tagged1 = time-tagged.All events are set to zero by default.(4)available as of version 9940 of SFT 2800.2/11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!