13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Neutral voltage displacement protectionANSI code59Nfunction n° F39X for Vo neutral voltage displacement 1 ≤ X ≤ 2F41X for Vo’ neutral voltage displacementEquipmentc single-phase <strong>and</strong> three-phase voltage generatorsc voltmetersc chronometerc calculatorc documentationWiringc diagram B4 or B7c protective relays:F391/1, F391/2F392/1, F392/2F411/1, F411/2F412/1, F412/2Testc read the section entitled measurement <strong>and</strong> testingmethodc status parameter settingv select Fn network frequency (50 or 60 Hz)v set Unp network phase-to-phase voltagev select the number of connected VTs given thatmeasurement by the sum of Vo voltages can only beused with 3 VTsv set Uns VT secondary circuit phase-to-phasevoltagev select Vnso the VT secondary circuit value whichenables Vo to be measured(Uns/1.732 or Uns/3 or sum of 3 Vs)v check the microswitches on the 3U/Vo moduleMicroswitch setting determines the Vo measurementmethod, i.e.:- no Vo measurement- measurement by open delta star VT of secondaryvalue Uns/1.732 or Uns/3 (A1-A2 inputs)- measurement by the sum of the 3 voltages(A1-A6 connection)Procedurec protection parameter setting: N Vol Dispv set Uso to the desired valuev set T to the desired valuev disable the lowest protection set point <strong>and</strong> P Seq U/V XTesting by injection with sum of the 3 voltages (diagram B4)Cut off <strong>Sepam</strong>'s 2000 auxiliary power supply to set the microswitches (SW1).Measurement of Voby sum of 3VTsSum of3 VTsTesting of set pointc status parameter settingv select number = 3Uv select Vnso = sum 3Vc protection parameter setting: N Vol Dispv set Vso to the desired valuev set T to 0.05 sv wire all the voltage inputsc testv gradually increase one of the voltages (leaving the other 2 voltages at zero) untilthe output relay picks upv read the voltage value on the voltmeter <strong>and</strong> on the pocket terminalThe value will be: u = Vsov stop injectionv press reset (1) on <strong>Sepam</strong> 2000 to erase the messages <strong>and</strong> reset the output relayTesting of time delay T (sum of VTs)c protection parameter setting: N Vol Dispv set T to the desired valuec testv prepare the injection with 1.2 times the value of Vso (see above)v set the chronometer to zerov start injection <strong>and</strong> the chronometer at the same timev <strong>Sepam</strong>'s 2000 output relay stops the chronometerv read the value measured by the chronometerIt is possible to conduct the test with a single-phase voltage generator.Remember to short-circuit the 2 voltage inputs which are not being used viaterminal A2.Example: microswitches set for sum of VTsc status parameter settingv Unp = 20 kVv Uns = 100 Vv number = 3Uv Vnso = 3 Vc protection parameter settingv Uso = 11.5 kVv T = 0.5 sFor an injection of u > 57.7 V, in accordance with diagram B4, into one of the phasevoltage inputs (the others = 0), the protection will trip after a period T = 0.5 s.(1)remember to reactivate the protections at the end of testing.X = number of the protective relay.1/36<strong>Sepam</strong> 2000 - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!