Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Use - commissioningCommissioning (cont’d)Program logic<strong>and</strong> annunciation<strong>Sepam</strong> 2000 comprises st<strong>and</strong>ard program logic for operation in the mostcommonly used installations. The logic is adapted to suit each application diagramby parameter setting at the time of commissioning.If <strong>Sepam</strong> 2000 is customized, the parameters may serve a different purpose:please refer to the information package supplied by your OEM.Resource <strong>and</strong> program logic chartfunction item item remarksfor S26, S36 for S25, S35logic input status I1, I2 I1, I2 1 = input suppliedI11 to I38 I11 to I38 0 = input not suppliedoutput relay status O1, O2 O1, O2 1 = contact closedO11 to O34 O11 to O34 0 = contact openinternal relay status K1 to K512 K1 to K256 1 = contact closed; 0 = contact openstored bistable status B1 to B128 B1 to B32 1 = contact closed; 0 = contact opencounter contents C1 to C24 C1 to C16 readtime delay output status T1 to T60 T1 to T60 set between 50 ms <strong>and</strong> 655 s via numeric <strong>and</strong> <strong>units</strong> keysparameters:latched contacts KP1 to KP16 <strong>and</strong> KP1 to KP16 set to 1 or 0 via data + <strong>and</strong> - keysKP33 to KP48 or numeric keys 0 <strong>and</strong> 1latched contacts KP17 to KP32 KP17 to KP32impulse contactsKP49 to KP64remote <strong>control</strong> contactslatched contacts KTC1 to KTC32 KTC1 to KTC32 contacts set to 1 or 0 via a remoteimpulse contacts KTC33 to KTC96 KTC33 to KTC64 <strong>control</strong> <strong>and</strong> monitoring systemremote indication contacts KTS1 to KTS64 KTS1 to KTS32 contacts set to 1 or 0 for reading by the remote <strong>control</strong> <strong>and</strong>monitoring systemalarm messages Bl1 to Bl16 not available reading of the last 16 automation activated messages(even if erased from display)For further information on the <strong>control</strong> <strong>and</strong> annunciation functions, refer to the document entitled “Control <strong>and</strong> monitoring functions” Réf 3140748.Connection of logic inputsESB <strong>Sepam</strong> <strong>Sepam</strong> <strong>Sepam</strong> <strong>Sepam</strong> <strong>Sepam</strong> (2)ESTOR1 motors substations transfor- capacitors generatorsbusbars mersI1 closed position c c c c c (2)I2 open position c c c c c (2)I11 earthing switch position: c c c c c (2)contact open for earthing switch openI12 load shedding: NO contact creceive "blocking input" c c cinhibit recloser c (1)VT circuit: contact closed for power ONI13 opening order: NC contact for shunt trip coil, c c c c c (2)NC contact for undervoltage release coilI14 close: NO contact c c c c c (2)I15 external protection tripping: NC or NC contact c c c c c (2)according to set upI16 pole pressure: contact closed for c c c c c (2)"breaking pole fault"I17 "drawn out" position: c c c c c (2)contact closed for "drawn out"I18 remote <strong>control</strong> enable: enables closing c c c c c<strong>and</strong> acknowledgment: contact closed for enable(1)for substation application with recloser(2)except for G00cInput I12 is used to inhibit the recloserinput I12 recloser status0 enabled/disabled status1 inhibitedIf locking takes place while a reclosing cycle is in progress, reclosing is instantlyinhibited.2/18 Installation - Use - General characteristics - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!