c testing of TOnce the protection activation zone has beendetermined, the T tests are the same as the definitetime <strong>and</strong> IDMT curve phase overcurrent protectiontests (see section on phase overcurrent).c testing of protective relay normal <strong>and</strong> inversezonesThe zone limits are: ϕ = 90° + θ to ϕ = 270° + θv inject phase-to-phase voltage Unsv set T to 0.05 sv select θ according to the different examples givenbelowv preset the current to twice Is <strong>and</strong> the phase shiftaccording to the chartv stop current injection <strong>and</strong> reset <strong>Sepam</strong> 2000 (1)v inject the current with a phase shift that is outsidethe zone concerned by the protective relay to betestedv vary the phase shift angle a of the injection unit soas to determine the angle limits of the activation zonev reset to zero when leaving the zone each time theoutput relay (1) is activated.c three-phase testingThese tests are performed using the same procedures as those describedpreviously.v connect the voltages (N, V1, V2, V3) <strong>and</strong> currents according to diagram B6v inject the voltages <strong>and</strong> currentsv the change in the injection box phase difference angle is determined by theprotection activation zone (see chart).characteristic normal zone inverse zoneangle F51X/1 <strong>and</strong> F51X/2 F51X/3 <strong>and</strong> F51X/4F52X/1 <strong>and</strong> F52X/2F52X/3 <strong>and</strong> F52X/4ϕ1 or ϕ2 or ϕ3ϕ1 or ϕ2 or ϕ3θ = 30° 300° … (0°) … to … 120° 120° … (180°) … to … 300°θ = 45° 315° … (0°) … to … 135° 135° … (180°) … to … 315°θ = 60° 330° … (0°) … to … 150° 150° … (180°) … to … 330°RemarkAs a rule, the angle indicated by the injection unit is the phase shift between phasevoltage <strong>and</strong> current.Exampleinjection unitpocket terminalαϕ+ 180° 180°+ 90° 270°0° 0° ou 360°- 90° 90°- 180° 180°The voltage is created electronically <strong>and</strong> is shifted with respect to the current thatserves as the reference for phase shift measurement.(1)this function may only be activated if your program logichas been customized.X = number of the protective relay.<strong>Sepam</strong> 2000 - Testing1/13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!