13.07.2015 Views

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

Sepam - HV/MV Protection and control units (ENG) - Trinet

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

SETTING RECORD SHEETProject: .....................................................................................................Switchboard: .........................................................................................Panel: ...............................................................................................................................................................................................................................<strong>Sepam</strong> 2000 TransformerType of <strong>Sepam</strong> 2000 Tserial numberStatus menu parametersmenu name functionrated Fn network frequency 50 Hz 60 Hzfrequencyphase CT board 2 (ECM 1 or ECA) board 3 (ECM 2)ratio In CT rating or CSP (in Amps) A kA A kAIb basis current (in Amps) A kA A kAnumber number of current sensors I1-I3 I1-I2-I3 I1-I3 I1-I2-I3Io sensor board 2 (ECM 1 or ECA) board 3 (ECM 2)Ino residual current Sum 3I for CTmeasurement Sum1 3I or sum2 3I for CSP2 A core bal. CT 30 A core bal. CTCT + CSH 30 for S26, S36AkAAkA for S25, S35core bal. CT + ACE 990AkAmax. dem<strong>and</strong> interval max. dem<strong>and</strong> 5 mn 10 mn 15 mn 30 mninterval integration time 60 mnVT ratio number number of wired VTs V 1U 3U S26, S36U21 U21-U32 3U S25, S35Unp rated VT voltsprimary voltage kilovoltsUns rated VT 100 V 110 V 115 V 120 Vsecondary voltageVnso type of residual voltage Sum 3V Uns/ 3 Uns/3measurementpower flow incomer reverses the signs of power Incomer = cables to busbarsdirection feeder <strong>and</strong> energy measurements Feeder = busbars to cablesoscillography pretrig number of periodsbefore triggering event of thedisturbance recordingperiodscommuni- bauds transmission speed 300 600 1200 2400cation 4800 9600 19200 38400address <strong>Sepam</strong> station numberin networkparity transmission format even odd no paritytime tagging synchro type of synchronization via network via input I11used via input I21events KTS1 to 8KTS9 to 16N.B.: KTS17 to 24For each event, KTS25 to 32choose 0 or 1 KTS33 to 400 = not time-tagged KTS41 to 481 = time-tagged KTS49 to 56all events are set KTS57 to 64to 0 by defaultI1 I2I11 to I18KTS33 to 64 for S26, S36 I21 to I28onlyI31 to I384/12 Installation - Use - General characteristics - Testing

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!