Protection Function Parameters: L<br />

•Motor Overload: L1<br />

Parameter<br />

Number<br />

L1-01<br />

Name<br />

Display<br />

Motor protection<br />

selection<br />

MOL Fault<br />

Select<br />

Motor protection<br />

time constant<br />

L1-02<br />

MOL Time<br />

Const<br />

Description<br />

Sets whether the motor thermal overload<br />

protection function is enabled or<br />

disabled.<br />

0: Disabled<br />

1: General-purpose motor protection<br />

(fan cooled motor)<br />

2: Inverter motor protection<br />

(externally cooled motor)<br />

3: Vector motor protection<br />

When the Inverter power supply is<br />

turned off, the thermal value is<br />

reset, so even if this parameter is<br />

set to 1, protection may not be<br />

effective.<br />

Sets the electric thermal detection time<br />

in seconds units.<br />

Usually changing this setting is not<br />

necessary.<br />

The factory setting is 150% overload<br />

for one minute.<br />

When the motor's overload capability<br />

is known, also set the overload resistance<br />

protection time for when the<br />

motor is hot started.<br />

Setting<br />

Range<br />

Factory<br />

Setting<br />

Control Methods<br />

V/f<br />

Open<br />

Loop<br />

Vector<br />

Closed<br />

Loop<br />

Vector<br />

Change<br />

during<br />

Operation<br />

MEMO-<br />

BUS<br />

Register<br />

Page<br />

0 to 3 1 No Q Q Q 480H 5-38<br />

0.1 to<br />

5.0<br />

1.0 min No A A A 481H 5-38<br />

•Power Loss Settings: L2<br />

Parameter<br />

Number<br />

Name<br />

Display<br />

Description<br />

Setting<br />

Range<br />

Factory<br />

Setting<br />

Control Methods<br />

V/f<br />

Open<br />

Loop<br />

Vector<br />

Closed<br />

Loop<br />

Vector<br />

Change<br />

during<br />

Operation<br />

MEMO-<br />

BUS<br />

Register<br />

Page<br />

L2-05<br />

Undervoltage<br />

detection level<br />

PUV Det Level<br />

Sets the DC bus undervoltage<br />

(UV) detection level (DC bus<br />

voltage).<br />

Usually changing this setting is<br />

not necessary.<br />

150 to<br />

210<br />

*1<br />

190VDC<br />

*1<br />

No A A A 489H --<br />

Battery Voltage<br />

L2-11<br />

Volt@batterydr<br />

Sets the battery voltage. 0 to 400 0VDC No A A A 4CBH 5-68-<br />

* 1. These are values for a 200 V class Inverter. The value for a 400 V class Inverter is the double.<br />

4-30