•Reference Detection: L4<br />
Parameter<br />
Number<br />
Name<br />
Display<br />
Description<br />
Setting<br />
Range<br />
Factory<br />
Setting<br />
Control Methods<br />
V/f<br />
Open<br />
Loop<br />
Vector<br />
Closed<br />
Loop<br />
Vector<br />
Change<br />
during<br />
Operation<br />
MEMO-<br />
BUS<br />
Register<br />
Page<br />
L4-01<br />
Speed agreement<br />
detection level<br />
Spd Agree Level<br />
Effective when "f out /f set agree 1",<br />
"Frequency detection 1" or "Frequency<br />
detection 2" is set for a<br />
multi-function output.<br />
0.0 to<br />
120.0<br />
0.0 Hz No A A A 499H 5-23<br />
L4-02<br />
Speed agreement<br />
detection width<br />
Spd Agree Width<br />
Effective when "f ref /f out agree 1",<br />
"f out /f set agree 1" or "Frequency<br />
detection 1" or "Frequency detection<br />
2" is set for a multi-function<br />
output.<br />
0.0 to<br />
20.0<br />
2.0 Hz No A A A 49AH 5-23<br />
L4-03<br />
Speed agreement<br />
detection level (+/-)<br />
Spd Agree Lvl+-<br />
Effective when "f out /f set agree 2",<br />
"Frequency detection 3" or "Frequency<br />
detection 4" is set for a<br />
multi-function output.<br />
-120.0 to<br />
+120.0<br />
0.0 Hz No A A A 49BH 5-23<br />
L4-04<br />
0.0 to<br />
20.0<br />
2.0 Hz No A A A 49CH 5-23<br />
•Fault Restart: L5<br />
Speed agreement Effective when "f ref /f out agree 2"<br />
detection width (+/-) "f out /f set agree 2", "Frequency<br />
detection 3" or "Frequency detection<br />
4" is set for a multi-function<br />
Spd Agree Wdth+output.<br />
Parameter<br />
Number<br />
L5-01<br />
L5-02<br />
Name<br />
Display<br />
Number of auto<br />
restart attempts<br />
Num of Restarts<br />
Auto restart operation<br />
selection<br />
Restart Sel<br />
Description<br />
Sets the number of auto restart<br />
attempts.<br />
Automatically restarts after a<br />
fault The retry fault code are the<br />
followings<br />
OV, UV1, GF, OC, OL2, OL3,<br />
OL4, UL3, UL4, PF, LF, SE1,<br />
SE2, SE3<br />
Sets whether a fault contact output<br />
is activated during fault<br />
restart.<br />
0: No output (Fault contact is<br />
not activated.)<br />
1: Output (Fault contact is<br />
activated.)<br />
Setting<br />
Range<br />
Factory<br />
Setting<br />
Control Methods<br />
V/f<br />
Open<br />
Loop<br />
Vector<br />
Closed<br />
Loop<br />
Vector<br />
Change<br />
during<br />
Operation<br />
MEMO-<br />
BUS<br />
Register<br />
Page<br />
0 to 10 2 No A A A 49EH 5-71<br />
0 or 1 1 No A A A 49FH 5-71<br />
4-32