•Storing Inverter set values in the Digital Operator/Monitor (READ)<br />

To store Inverter set values in the Digital Operator/Monitor use the following method.<br />

Table 5.1 READ Function Procedure<br />

Step<br />

No.<br />

Explanation<br />

Digital Operator/Monitor Display<br />

1 Press the Menu Key and select advanced programming mode.<br />

-ADV-<br />

** Main Menu **<br />

Programming<br />

2 Press the DATA/ENTER Key.<br />

-ADV-<br />

Initialization<br />

A1 - 00=1<br />

Select Language<br />

3<br />

Press the Increment and Decrement Key until parameter o3-01 is displayed (Copy Function<br />

Selection).<br />

-ADVo3<br />

- 01=0<br />

COPY Function<br />

Copy Funtion Sel<br />

4 Press the DATA/ENTER Key and select the constants setting display.<br />

-ADV-<br />

Copy Function Sel<br />

o3-01= 0 *0*<br />

COPY SELECT<br />

5 Change the set value to 1 using the Increment Key.<br />

-ADV-<br />

Copy Function Sel<br />

o3-01= 1 *0*<br />

INV OP READ<br />

6 Set the changed data using the DATA/ENTER Key. The READ function will start.<br />

INV OP READING<br />

7 If the READ function ends normally, “End” is displayed on the Digital Operator/Monitor.<br />

-ADV-<br />

READ<br />

-ADV-<br />

READ<br />

READ COMPLETE<br />

8 The display returns to o3-01 when a key is pressed.<br />

-ADV-<br />

Copy Function Sel<br />

o3 - 01=0 *0*<br />

COPY SELECT<br />

If an error is displayed, press any key to cancel the error display and return to the o3-01 display. Refer to<br />

page 6-14, Digital Operator Copy Function Faults for corrective actions.<br />